3M eg4, eg3 user manual Range of sound

Page 9

3

Dosimetry

Range of sound

Sound pressure is measured in decibels, or tenths of a Bel. Sound pressure level is indicated as dB SPL. Since the human ear can detect sounds with an extensive range of amplitude, a decibel scale is used to simplify the measurement results. For example, the ratio between the threshold of hearing and threshold of pain in the human ear if measured in true energy is 10,000,000 times! The same range using the dB scale is 0 - 140 dB referenced to 20 µPa (Micropascals).

The quietest sound that humans can hear has an amplitude of approximately 0 dB. Prolonged exposure to sound pressure levels exceeding 85 dB can cause permanent damage to the ear. Sound levels in excess of 130 dB are more than the human ear can safely withstand and can result in serious pain and permanent damage.

Many organizations have studied and analyzed the effects of high sound exposure on hearing. As a result, standards were developed to regulate personal noise exposure. In the United States, the Occupational Safety and Health Administration (OSHA), the Mine and Safety and Health Administration (MSHA), and the American Conference of Governmental Industrial Hygienists (ACGIH) have all created regulations and limitations on total permissible noise exposure. International standards are specified by the health and safety regulations such as the European Union (EU) Directive 2003/10/EC. Additionally, the International Electrotechnical Commission (IEC) IEC-61252 has specific guidelines and regulations to monitor noise in the workplace.

To access these copyrighted standards, please refer to the following:

OSHA - http://www.osha.gov

MSHA- http://www.msha.gov

NIOSH - http://www.cdc.gov/niosh/topics/noise

ACGIH - http://www.acgih.org/

IEC - http://www.iec.ch

053-644, Rev E

Page 3

eg4 & eg3

Image 9
Contents Edge Getting started Checking the equipment Turning on Introduction DosimetryTurning off Display and keypad 3MTMDetection Mangement Software DMSViews on the Edge Noise studiesDocking Running studiesStopping a study Appendix a Specifications StandardsTechnical Support User InterfacePhysical attributes of EdgeDock1 and EdgeDock5 Contacting 3M Quest Technologies International customersINDEX………………………………………………………………………………… List of Tables Introduction Illustration of how the dosimeter operates and processes Range of sound Time history manufacturing Peak Measurement 121.20 dB Running your studies Setting-up your dosimeter parameters for your noise studiesView your results via QSP-II Develop corrective actionsParameter setup screen for eg4 Getting started Powered on with measurement view displayed Edge LED Explanation Indicator LED indicators explainedEdge Keypad EdgeDock1 EdgeDock1 and EdgeDock5 components Attaching charger adapter to EdgeDock1 and EdgeDock5  Powering EdgeDock1 or EdgeDock5Docking the Edge with a single and 5-bay docks  How to chargeBackside of EdgeDock1 Setting-up the Edge via DMS Sample summary data from DMS reporting Logging Dosimeter views and definitions Views on ExplanationViews on Explanation Edge WeightingDose Response LevelDosimeter measurement descriptors/variants Descriptors Variants Lmax variantsCommunicating connecting a docked Edge to a pc New Hardware wizard for Edge Dock Dosimeter screen Dosimeter fields explained for the Edge Edge display screen Edge security setting Edge auto run screen 10 Edge firmware update screen 11 Saving and sending Edge setups Quick help list for running a study Quick Help List typical dosimetry sessionPositioning/Attaching the Edge  How to attach the dosimeterBattery indicators  Checking battery powerCalibrating  Calibrating the dosimeterOn/off enter  Reset Contrast On/off/enter buttonContrast icon Checkmark icon Is the selection to Display screen while running  How to run a noise study How to stop a noise study Indicator Icon ExplanationIndicators i.e., run, stop, battery, and OL Measurement view on the Edge  Viewing measurements How to unlock  How to lock or secureCommunicating between your pc and the Edge  DownloadingDMS start screen  Selecting and viewing data Recent downloaded dataExample of Edge Report in DMS Panel layout view viewing the data in charts and graphs Technical Support  Attaching/Detaching the windscreen and microphone Microphone and windscreen assemblyHard Hat Attachment Kit Housing WeightSize Type LifeMemory capacity OperatingLED Red indicator LED amber indicatorLED Green indicator Size of EdgeDock1Displayed Data Status indicatorsDosimeters RMS RangeSecurity Auto-RunLogging eg4 only Analog Board Edge Block Diagram International customers Service Department and Technical Support 1 800Background Noise, effects Combining Noise sources Crest FactorCriterion Level CL Decibel dB Criterion TimeDose Exchange Rate ER also known as the Doubling RateHearing Conservation HC Hertz Hz Free field setting microphoneLavg Average Level Lep,dLogging Leq Equivalent LevelMaximum Level Lmax Measurement RangeProjected Time PEL Permissible Exposure LevelRandom incidence microphone Response TimeThreshold TWA Time Weighted AverageWeighting A, C, Z, etc Upper Limit ULWindscreen Dose = Edge Dock IndexRunning studies QSP-II
Related manuals
Manual 75 pages 23.92 Kb