3M eg4, eg3 user manual Background Noise, effects

Page 63

57

 

APPENDIX

Appendix B

B

Glossary of Terms

Background Noise, effects of

Background noise can cause considerable error in measurement when its level is high relative to the level of a noise source of interest. If you can make measurements both with and without the contribution of a noise source of interest, you can mathematically subtract the background noise from the combined measurement, yielding the level of the noise source of interest alone. The accuracy of this determination improves as the difference between the two measurements increases.

To remove background noise

1.Obtain a measurement that includes the contribution of the noise source of interest (the combined measurement).

2.Make a second measurement under exactly the same conditions as in Step 1 but without the presence of the noise source of interest (the background noise measurement).

3.Determine the decibel difference between these two measurements.

4.Find that difference on the x-axis of the figure below.

5.Find the point on the curve directly above this difference.

6.Read the corresponding value on the y-axis for that point (the correction value).

7.Subtract the correction value from the combined measurement.

Example: Measurements with and without the noise source of interest are 91 dB and 90 dB, respectively. For a difference of 1 dB, the background noise correction value is 7 dB. Therefore the level for the noise source of interest without the noisy background is 84 dB.

053-644, Rev E

Page 57

eg4 & eg3

Image 63
Contents Edge 3MTMDetection Mangement Software DMS Introduction DosimetryGetting started Checking the equipment Turning on Turning off Display and keypadRunning studies Noise studiesViews on the Edge DockingUser Interface Appendix a Specifications StandardsStopping a study Technical SupportPhysical attributes of EdgeDock1 and EdgeDock5 Contacting 3M Quest Technologies International customersINDEX………………………………………………………………………………… List of Tables Introduction Illustration of how the dosimeter operates and processes Range of sound Time history manufacturing Peak Measurement 121.20 dB Develop corrective actions Setting-up your dosimeter parameters for your noise studiesRunning your studies View your results via QSP-IIParameter setup screen for eg4 Getting started Powered on with measurement view displayed Edge LED Explanation Indicator LED indicators explainedEdge Keypad EdgeDock1 EdgeDock1 and EdgeDock5 components Attaching charger adapter to EdgeDock1 and EdgeDock5  Powering EdgeDock1 or EdgeDock5Docking the Edge with a single and 5-bay docks  How to chargeBackside of EdgeDock1 Setting-up the Edge via DMS Sample summary data from DMS reporting Logging Dosimeter views and definitions Views on ExplanationResponse Level WeightingViews on Explanation Edge DoseDosimeter measurement descriptors/variants Descriptors Variants Lmax variantsCommunicating connecting a docked Edge to a pc New Hardware wizard for Edge Dock Dosimeter screen Dosimeter fields explained for the Edge Edge display screen Edge security setting Edge auto run screen 10 Edge firmware update screen 11 Saving and sending Edge setups Quick help list for running a study Quick Help List typical dosimetry sessionPositioning/Attaching the Edge  How to attach the dosimeterBattery indicators  Checking battery powerCalibrating  Calibrating the dosimeterOn/off enter  Reset Contrast On/off/enter buttonContrast icon Checkmark icon Is the selection to Display screen while running  How to run a noise study How to stop a noise study Indicator Icon ExplanationIndicators i.e., run, stop, battery, and OL Measurement view on the Edge  Viewing measurements How to unlock  How to lock or secureCommunicating between your pc and the Edge  DownloadingDMS start screen  Selecting and viewing data Recent downloaded dataExample of Edge Report in DMS Panel layout view viewing the data in charts and graphs Technical Support  Attaching/Detaching the windscreen and microphone Microphone and windscreen assemblyHard Hat Attachment Kit Housing WeightSize Operating LifeType Memory capacitySize of EdgeDock1 LED amber indicatorLED Red indicator LED Green indicatorRMS Range Status indicatorsDisplayed Data DosimetersSecurity Auto-RunLogging eg4 only Analog Board Edge Block Diagram International customers Service Department and Technical Support 1 800Background Noise, effects Combining Noise sources Crest FactorCriterion Level CL Exchange Rate ER also known as the Doubling Rate Criterion TimeDecibel dB DoseLep,d Free field setting microphoneHearing Conservation HC Hertz Hz Lavg Average LevelMeasurement Range Leq Equivalent LevelLogging Maximum Level LmaxResponse Time PEL Permissible Exposure LevelProjected Time Random incidence microphoneThreshold TWA Time Weighted AverageWeighting A, C, Z, etc Upper Limit ULWindscreen Dose = Edge Dock IndexRunning studies QSP-II