Setup and Calibration

(s9) LOG UNITS

The units in which ALL distance related information is displayed. Nautical Miles (NM), Kilometres (KM) or Statute Miles (SM).

(s10) TEMP UNITS

The units in which the Sea Temperature reading is displayed. Degrees Celsius (0C) or Degrees Fahrenheit (0F).

3.4.3 Alarms Chapter

In each case press the button quickly to edit, press the or

to change values and press the button quickly to save the

entered value. In the case of On/Off selection the button will toggle the setting On and Off. Default values are indicated in bold.

(s11) DEPTH SHALL

Sets the Shallow Depth at which the instrument will alarm. OFF and 0 to 7.6m (0 to 25 ft.) (0 to 4 ftms). Values are displayed in the previously selected units (see page 18 -s7) and are all subject to any keel or waterline offset added (see page 20 -s21). This alarm sounds as the depth passes below the set value and NOT as the depth increases past this value.

(s12) DEPTH DEEP

Sets the Deep Depth at which the instrument will alarm. OFF and 0 to 76.2m (0 to 250 ft.) (0 to 41.6 ftms). Values are displayed in the selected units (see page 18 -s7) and are all subject to any keel or waterline offset added (see page 23). This alarm sounds as the depth increases past this value or decreases past this value.

(s13) OFF CRSE

Sounds if the vessel moves further than the set distance away from a “Locked” heading (see page 19 -s12). Off/On

(s14) WIND HIGH

Sets the Wind Speed at which the instrument will alarm. OFF and 0.0 to 100 knots (0.0 to 51.4 m/s). Values are displayed in the previously selected units (see page 18 -s8). This alarm sounds as the wind speed increases past the set value and NOT as it decreases past this value.

21

Image 23
Contents Mn100 EMC Conformance Information Setup and CalibrationInstallation Maintenance and Fault FindingIntroduction SpecificationsPower Management and Battery Life Instrument Display Information Safety and Disposal Applying External PowerIntroduction Backlighting Switching the System On and OffAudible Signals and Alarms Chapter and Page Operation Page Chapters Chapter and Page DescriptionsPages Page Page XTE Time Current heading is 277 Current speed is 9.56 kts This page left intentionally blank Chapter and Page Setup and Calibration Entering Setup and Calibration ModeEditing Values Units Chapter Setup Page DescriptionMemory Chapter Alarms Chapter Depth Chapter Calibration Page DescriptionSpeed Chapter Compass Chapter Wind ChapterOptions Chapter Health Chapter Depth Offset To enter a Log Calibration Factor Speed CalibrationWind Speed Correction Wind CalibrationWind Angle Offset Compass Calibration Precautions and Positioning Advice Tools Required Parts ListBracket Mounting Preferred Method Temporary Mounting External Power Connections Fault Finding and Technical Support Care and MaintenanceMaintenance and Fault Finding No Nmea data showing on external instruments Warranty Information