MicroNet Technology MN100 manual Calibration Page Description, Speed Chapter, Depth Chapter

Page 24

mn100 Dual Digital Display

(s15) XTE LARGE

Sets the instrument to alarm if a Large Cross Track Error alarm is issued by the GPS. On/Off.

(s16) WP ARRVE

Sets the instrument to alarm if a Waypoint Arrival alarm is issued by the GPS. On/Off.

3.5Calibration Page Description

In each case press the button quickly to edit, press the or

to change units and press the button quickly to select the chosen units. Default values are indicated in bold.

Speed Chapter

(s17) RESP Spd

Sets the update period of the Speed display.

Auto/Slow/Medium/Fast

(s18) SPEED

Boat Speed Calibration Factor adds a percentage factor which corrects the information from the Speed Transducer and ensures the Boat Speed is displayed correctly. See page 24 for calibration.

(s19) SPEED FORMT

Sets the display to show Speed readings in a resolution of

0.1or 0.01 of the selected units.

(s20) SEA

Sea Temperature Calibration Factor adds a percentage factor which corrects the information from the temperature sensor and ensures the water temperature is displayed correctly.

Depth Chapter

(s21) KEEL OFSET

Allows a Keel Offset to be added allowing the instrument depth reading to indicate depth below the bottom of the boat, or a Waterline Offset allowing the depth reading to indicate Actual Water Depth. See page 23 for calibration.

22

Image 24
Contents Mn100 EMC Conformance Setup and Calibration InstallationMaintenance and Fault Finding InformationSpecifications Power Management and Battery LifeIntroduction Instrument Display Information Applying External Power Safety and DisposalIntroduction Switching the System On and Off BacklightingAudible Signals and Alarms Chapter and Page Operation Page Chapter and Page Descriptions ChaptersPages Page Page XTE Time Current heading is 277 Current speed is 9.56 kts This page left intentionally blank Entering Setup and Calibration Mode Chapter and Page Setup and CalibrationEditing Values Setup Page Description Memory ChapterUnits Chapter Alarms Chapter Calibration Page Description Speed ChapterDepth Chapter Wind Chapter Compass ChapterOptions Chapter Health Chapter Depth Offset Speed Calibration To enter a Log Calibration FactorWind Calibration Wind Angle OffsetWind Speed Correction Compass Calibration Tools Required Parts List Precautions and Positioning AdviceBracket Mounting Preferred Method Temporary Mounting External Power Connections Care and Maintenance Fault Finding and Technical SupportMaintenance and Fault Finding Warranty Information No Nmea data showing on external instruments