Performing a visual check

Damaged materials can cause injury. Parts damaged during transit can also be dangerous.Check the module for damage, missing parts or poor soldering. If you find damage, return the module for exchange.

Mounting the locomotive decoder

Open the locomotive housing. Locate the position for the decoder. Disconnect the motor from the rail current collector respectively the change-over switch from the motor and rails if you have a locomotive with electronic change-over switch.

!Caution:

The interference suppression devices mounted to the motor or the connecting wire must not be removed! Motor and interference suppression devices are one unit. If even one part is removed, it can cause extreme interference!

Connecting the LD-G-1

Follow the connections diagrams (fig. 4)! Solder the connections to the rails at points X1 and X2 (rear of the decoder) and the connections to the motor at the points X11 and X12 (rear of the decoder). The connection to the rails is optional, but you must observe polarity when connecting the motor.

Connecting the LD-W-1

Follow the connections diagrams (fig. 5)! Solder the connections to the rails at points X1 and X2 (rear of the decoder) and the connections to the motor at the points X11, X12 and X19 (rear of the decoder).

Connecting the lighting and other accessories

Follow the connections diagrams (fig. 3a and 3b)!

Disconnect any existing diodes in the leads to the lamps. Connect the lamps for forward motion to X4 and the lamps for reverse to point X5 (front of the decoder). If the lamps are already connected with one side to locomotive ground, you must solder in a diode between the decoder and the lamp (see

Page 28

Image 11
Contents LD-G-1n Anleitung 07/2002 Tams Elektronik GmbH NederlandsTable of contents Intended use How to use this manualElectrical hazards Safety instructionsMechanical hazards Other dangers Fire riskThermal danger Information Motorola I and Motorola II format EMC declarationOperation overview Checking the package contents Technical specificationsSafe and correct soldering Required tools and consumablesPerforming a visual check Connecting the LD-G-1Connecting the LD-W-1 Connecting the lighting and other accessoriesConnecting the LEDs Setting the driving characteristics Setting the locomotive decoderUsing an NEM 652 interface connector Setting the locomotive address Operation Emergency stop during active acceleration and brake delaySwitching the shunting gear Improvement of the driving characteristicsManufacturers note FAQCertification Conditional warrantyAdresse Lötfeld Soldering field Adresse Lötfeld Soldering field LD-G-1 / LD-W-1 Adresse Lötfeld Soldering field Adresse Lötfeld Soldering field LD-G-1LD-G-1 LD-W-1 LD-G-1 / LD-W-1 LD-G-1 / LD-W-1 Tams Elektronik GmbH