Motorola LD-W-1 manual Connecting the LEDs

Page 12

LD-G-1 / LD-W-1

English

fig. 3a) or you must connect the second side of the lamps according to fig. 3b to the return conductor (point X3 on the front of the decoder).

Connect other accessories (e.g. smoke generator, cab lighting), which are switched by the functions F1 to F4, to the points X7 to X10 (front of the decoder). You can connect the second side of the accessories either to the return conductor (point X3) or to locomotive ground. If connecting the accessory to locomotive ground you must solder in a diode.

!Caution:

The return conductor for all functions (point X3) must under no circumstances be connected to locomotive ground. Possible short circuit! The locomotive decoder will be damaged in operation.

Tip: If the second side of the lamps is connected to locomotive ground the lamps often flicker in operation. You can avoid the flickering of the lamps if you connect the second side to the return conductor (point X3) instead of locomotive ground.

!Caution:

If you connect the loads to the return conductor for all functions (point X3), the load must be insulated. The loads must not make contact with metal parts of the locomotive. Possible short circuit! The locomotive decoder will be damaged in operation.

Connecting the LEDs

The function outputs of the locomotive decoder switch against decoder ground. For that reason you must connect the cathode (-) of the LED to the output of the relevant function.

!Caution:

If you use light-emitting diodes (LEDs) you must always operate them via a series resistor.

LEDs are available in many different models. There are LEDs with 2-5 mA, but also LEDs with 15-30 mA power consumption. The series resistor limits the current flow of the LED and will need to be calculated for each model. Ask for the max current rating when buying your LEDs.

Page 29

Image 12
Contents LD-G-1n Anleitung Nederlands 07/2002 Tams Elektronik GmbHTable of contents How to use this manual Intended useSafety instructions Mechanical hazardsElectrical hazards Fire risk Thermal dangerOther dangers EMC declaration Information Motorola I and Motorola II formatOperation overview Technical specifications Checking the package contentsRequired tools and consumables Safe and correct solderingConnecting the LD-G-1 Connecting the LD-W-1Connecting the lighting and other accessories Performing a visual checkConnecting the LEDs Setting the locomotive decoder Using an NEM 652 interface connectorSetting the driving characteristics Setting the locomotive address Emergency stop during active acceleration and brake delay Switching the shunting gearImprovement of the driving characteristics OperationFAQ Manufacturers noteConditional warranty CertificationAdresse Lötfeld Soldering field Adresse Lötfeld Soldering field LD-G-1 / LD-W-1 Adresse Lötfeld Soldering field Adresse Lötfeld Soldering field LD-G-1LD-G-1 LD-W-1 LD-G-1 / LD-W-1 LD-G-1 / LD-W-1 Tams Elektronik GmbH