English |
FAQ
§Parts are getting too hot and/or start to smoke.
!Disconnect the system from the mains immediately! Possible cause: one or more connections are soldered incorrectly.
àCheck the connections.
Possible cause: The connection of the motor is connected to locomotive ground.
àDisconnect the connection from locomotive ground.
§The locomotive lighting does not correspond to its direction of travel. Possible cause: The forward and backward light connections have been exchanged.
àCheck the connections.
Possible cause: The connections of the motor to the points X11 and X12 have been exchanged.
àExchange the connections.
§A lamp flickers (this is not a defect).
Possible cause: The lamp is connected with one side to locomotive ground.
àIf you do not want the lamp to flicker, disconnect it from locomotive ground, insulate it and connect it to the return conductor (point X3).
§The locomotive does not run.
Possible cause: The locomotive address is not set correctly.
àCheck the solder bridges (if necessary with a magnifiying glass). If you cannot find the problem, please return the decoder for repair (address on the cover page).
Manufacturer's note
According to DIN VDE 0869, the person who builds this kit or brings the circuit into operation is the manufacturer of the product. If he sells the product to another person he is responsible for passing on all the
Page 33