Motorola LD-W-1 manual EMC declaration, Information Motorola I and Motorola II format

Page 7

English

LD-G-1 / LD-W-1

EMC declaration

This product is developed in accordance with the European standards EN 55014 and EN 50082-1, tested corresponding to the EC - directive 89/336/EWG (EMVG of 09/11/1992, electromagnetic tolerance) and meets legal requirements.

To guarantee the electromagnetic tolerance you must take the following precautions:

§Connect the transformer only to an approved mains socket installed by an authorised electrician.

§Make no changes to the original parts and accurately follow the instructions, circuit diagram and PCB layout included with this manual.

§Use only original spare parts if you have to repair the kit or the ready-built module.

Information: Motorola I and Motorola II format

The digital driving data is differently encoded and transmitted in the (old) Motorola I format and the (new) Motorola II format. The locomotive decoder is designed to evaluate data in Motorola II format. This limits its use in Motorola I format.

Since data of the auxiliary functions F1 to F4 sent in Motorola I Format cannot be evaluated by the locomotive decoder, it is not possible to switch these functions on or off when using Motorola I format.

Unlike the Motorola II format, no absolute direction data is sent in Motorola I format, but a single driving signal reverses the direction of travel. This has the following consequences:

1.If the change direction command is not recognized by the locomotive, it continues in the original direction.

2.If the decoder is switched off for some time and the direction data is not saved, the locomotive continues in its favourite direction when it is switched on again.

Page 24

Image 7
Contents LD-G-1n Anleitung 07/2002 Tams Elektronik GmbH NederlandsTable of contents Intended use How to use this manualMechanical hazards Safety instructionsElectrical hazards Thermal danger Fire riskOther dangers Information Motorola I and Motorola II format EMC declarationOperation overview Checking the package contents Technical specificationsSafe and correct soldering Required tools and consumablesPerforming a visual check Connecting the LD-G-1Connecting the LD-W-1 Connecting the lighting and other accessoriesConnecting the LEDs Using an NEM 652 interface connector Setting the locomotive decoderSetting the driving characteristics Setting the locomotive address Operation Emergency stop during active acceleration and brake delaySwitching the shunting gear Improvement of the driving characteristicsManufacturers note FAQCertification Conditional warrantyAdresse Lötfeld Soldering field Adresse Lötfeld Soldering field LD-G-1 / LD-W-1 Adresse Lötfeld Soldering field Adresse Lötfeld Soldering field LD-G-1LD-G-1 LD-W-1 LD-G-1 / LD-W-1 LD-G-1 / LD-W-1 Tams Elektronik GmbH