-Display: LCD 12 mm, function and photo-radiometric symbols.

-Functions: Automatic and manual change of scale, integration time up to 1999 hours, auto power off. Storage and updating of the Maximum, Minimum and Q (Energy) values. Optoinsulated serial output RS232C with adapter AD RS232C.

Analog output 1.9 mV/°C, 2.5 mV/lux, 250 mV/W.

-Power supply: 9V battery IEC 6LF22.

-Battery life: 150 hours with alkaline battery.

-Serial output: RS232C data transmission speed

300 baud

8 data bit length

1 start bit

1 stop bit

no parity

 

Use the optional adapter cable AD RS232C from SUB D female 9-pole to SUB D female 25 pole connectors. Manual or automatic transmission of the value displayed; at a fixed rate of once every 10 seconds.

CHARACTERISTICS OF THE INSTRUMENT WHEN MEASURING TEM- PERATURE WITH PROBES IN THE SERIES TP870

Measuring range: -200°C...+800°C (-392°F...+1472°F) in two scales with automatic change of scale.

Resolution: -200°C...+200°C = 0.1, above that =1°C

Precision with TP870 probe included: -50°C...+200°C (-58°F...+392°F) ±0.15% ±0.2°C ±1 digit

over ±0.3% ± 1°C ±1 digit.

At temperatures higher than 400°C, avoid violent blows or thermal shock to the temperature probes as they may cause irreparable damage to the sensor. Instrument container: ABS Bayer NOVODUR, black.

Weight of the instrument alone: 360 g

Weight of the kit: 2500 g

Dimensions of the instrument: 135x73x38 mm

Dimensions of the kit: 370x280x90 mm

– 40 –

Image 18
Contents Instructions Manual 22 23 24 Quantum Photo Radiometer Key for activating the display of input a Input B socket, DIN 8-pole connectorMAN key for choosing the working scale manually Key for activating the display of input BLx/fcd Ding in C or FCount of the time elapsed Shes DataAutomatic Seconds, minutes or hours Is being takenThreshold this key is used to DisabledIf a high value is to be set Decrease the set valueOFL HOW to MeasureErr Probe ConnectionMethod of USE LOW Battery Warning Data bit length Start bit MaintenanceSerial Output Stop bit no parityAnalog Output AD RS 232CBlock Diagram Layout of Components Calibrating the Instrument HD Series HD 9021 Probe CalibrationCharacteristics Technical FeaturesMeasurements and measuring ranges Display LCD 12 mm, function and photo-radiometric symbols Start bit Stop bit No parityOver ±0.3% ± 1C ±1 digit Order Code CorrectionSer for cosine correction Probes Typical response curve of the probe is as followsHD 9021 RAD/C HD 9021 RAD/PARTypical response curve of the probe is as follows HD 9021 UVA Producing erythematous action in the fieldBlack light in the field Producing bactericide germicide action in the fieldHD 9021 UVB HD 9021 UVCLux lx HD 9021/CdLight flux Nit nitSafety EN61000-4-2, EN61010-1 levelVoltage variations