Quantum HD 9021 manual Safety, EN61000-4-2, EN61010-1 level, Voltage variations

Page 26

 

 

 

 

ENGLISH

 

 

 

 

 

 

 

CE CONFORMITY

 

 

Safety

 

EN61000-4-2, EN61010-1 level 3

 

 

Electrostatic

 

EN61000-4-2 level 3

 

 

discharge

 

 

 

 

 

 

 

 

Electric fast

 

EN61000-4-4 level 3

 

 

transients

 

 

 

 

 

 

 

 

Voltage variations

 

EN61000-4-11

 

 

Electromagnetic

 

 

 

 

 

interference

 

IEC1000-4-3

 

 

sucseptibility

 

 

 

 

 

Electromagnetic

 

 

 

 

 

interference

 

EN55020 class B

 

 

emission

 

 

 

 

GUARANTEE CONDITIONS

All our appliances have been subjected to strict tests and are guaranteed for 24 months from date of pur- chase. The Company undertakes to repair or replace free of charge any parts which it considers to be inef- ficient within the guarantee period. Complete replacement of the instrument is excluded and no requests for damages are recognized, whatever their origin. Repairs are carried out in our own Technical Service Department. Transport expenses are borne by the buyer. The guarantee does not include: accidental breakages due to transport, incorrect use or neglect, incorrect connection to voltage different from that contemplated for the instrument, probes, sensors, electrodes and all accessories. Furthermore the guarantee is not valid if the instrument has been repaired or tampered with by unauthorized third par- ties, or adjusted for faults or casual checking. The guarantee is valid only if all parts of the guarantee card have been filled in. Any instruments sent for repairs must be accompanied by their guarantee certificate. For all disputes the competent court is the Court of Padua.

SIT CALIBRATION

CENTRE N° 124

DELTA OHM SRL

VIA G. MARCONI, 5 - 35030 CASELLE DI SELVAZZANO (PD) - ITALY TEL. 0039-0498977150 r.a. - FAX 0039-049635596

e-mail: deltaohm@tin.it - Web Site: www.deltaohm.com

– 48 –

Image 26
Contents Instructions Manual 22 23 24 Quantum Photo Radiometer Key for activating the display of input a Input B socket, DIN 8-pole connectorMAN key for choosing the working scale manually Key for activating the display of input BCount of the time elapsed Lx/fcdDing in C or F Automatic ShesData Seconds, minutes or hours Is being takenThreshold this key is used to DisabledIf a high value is to be set Decrease the set valueOFL HOW to MeasureErr Probe ConnectionMethod of USE LOW Battery Warning Data bit length Start bit MaintenanceSerial Output Stop bit no parityAnalog Output AD RS 232CBlock Diagram Layout of Components Calibrating the Instrument HD Series HD 9021 Probe CalibrationMeasurements and measuring ranges CharacteristicsTechnical Features Over ±0.3% ± 1C ±1 digit Display LCD 12 mm, function and photo-radiometric symbolsStart bit Stop bit No parity Ser for cosine correction Order CodeCorrection Probes Typical response curve of the probe is as followsHD 9021 RAD/C HD 9021 RAD/PARTypical response curve of the probe is as follows HD 9021 UVA Producing erythematous action in the fieldBlack light in the field Producing bactericide germicide action in the fieldHD 9021 UVB HD 9021 UVCLux lx HD 9021/CdLight flux Nit nitVoltage variations SafetyEN61000-4-2, EN61010-1 level