Quantum HD 9021 manual Order Code, Correction, Ser for cosine correction

Page 19

ENGLISH

ORDER CODE

HD 9021 K : The kit is composed of the HD 9021 instrument, diplomatic carrying case, without probe.

HD 9021 : Photometric probe for measuring light, illuminance, photopic

PHOT/C correction filter complying with CIE, diffuser for cosine correc- tion. Range 0÷200,000 lux.

HD 9021 : Radiometric probe for measuring light energy, irradiance,

RAD/C radiometric filter, diffuser for cosine correction. Range 400÷900 nm.

HD 9021 : Radiometric probe for measuring radiations in the field of the RAD/PAR PAR chlorophyll process (Photosynthetically Active Radiation 400÷700 nm), measurements in µEinstein, diffuser for cosine

correction.

HD 9021 : Radiometric probe for measuring radiation, irradiance, in the RAD/UVA UVA wave length 315÷400 nm, peak at 365 nm. Quartz diffu-

ser for cosine correction.

HD 9021 : Radiometric probe for measuring radiation, irradiance, in the RAD/UVB UVB wave length 280÷315 nm, peak at 312 nm. Quartz diffu-

ser for cosine correction.

HD 9021 : Radiometric probe for measuring radiation. irradiance, in the RAD/UVC UVC wave length 190÷280 nm, peak at 250 nm. Quartz diffu-

ser for cosine correction.

HD 9021/Cd: Photometric probe for measuring luminance, photopic correc- tion filter complying with CIE. Measuring range from 0 to 200 cd/cm2.

AD RS232C : Connecting cable from SUB D female 9-pole to SUB D female 25 pole, complete with electronics, for serial output RS232C.

TP 870 : Immersion temperature probe, Pt100 sensor, diam. 3x230 mm, range -60°C...+400°C.

TP 870C : Surface temperature probe, Pt100 sensor, diam. 4x230 mm, range -60°C...+400°C.

TP 870P : Penetration temperature probe, Pt100 sensor, diam. 4x150 mm, range -60°C...+400°C.

TP 870A : Air temperature probe, Pt100 sensor, diam. 4x230 mm, range -60°C...+300°C.

– 41 –

Image 19
Contents Instructions Manual 22 23 24 Quantum Photo Radiometer Key for activating the display of input B Input B socket, DIN 8-pole connectorMAN key for choosing the working scale manually Key for activating the display of input aDing in C or F Lx/fcdCount of the time elapsed Data ShesAutomatic Is being taken Seconds, minutes or hoursDecrease the set value DisabledIf a high value is to be set Threshold this key is used toProbe Connection HOW to MeasureErr OFLMethod of USE LOW Battery Warning Stop bit no parity MaintenanceSerial Output Data bit length Start bitAD RS 232C Analog OutputBlock Diagram Layout of Components Series HD 9021 Probe Calibration Calibrating the Instrument HDTechnical Features CharacteristicsMeasurements and measuring ranges Start bit Stop bit No parity Display LCD 12 mm, function and photo-radiometric symbolsOver ±0.3% ± 1C ±1 digit Correction Order CodeSer for cosine correction Typical response curve of the probe is as follows ProbesHD 9021 RAD/PAR HD 9021 RAD/CTypical response curve of the probe is as follows Producing bactericide germicide action in the field Producing erythematous action in the fieldBlack light in the field HD 9021 UVAHD 9021 UVC HD 9021 UVBNit nit HD 9021/CdLight flux Lux lxEN61000-4-2, EN61010-1 level SafetyVoltage variations