Quantum manual HD 9021 RAD/C, HD 9021 RAD/PAR

Page 21

ENGLISH

HD 9021 RAD/C

Radiometric probe for measuring the IRRADIANCE of light sources, irra- diance of the sun, etc. Radiometric filter and diffuser for angle correction according to the cosine law. Spectral measurement range 400÷900 nm, range from 1 microwatt/cm2 to 200 milliwatt/cm2. The probe is used in greenhouses for measuring the power of artificial light, shade, the perfor- mance of solar panels, solar heating plants, solar filters, etc.

The typical response curve of the probe is as follows:

1.00

0.90

0.80

0.70

0.60

0.50

0.40

0.30

0.20

0.10

380.0

460.0

540.0

620.0

700.0

780.0

860.0

940.0

1020

1100

HD 9021 RAD/PAR

Radiometric probe for measuring PAR radiations (Photosynthetically Active Radiation), works in the field of the chlorophyll process following a special response curve in a spectral range from 400 to 700 nm. The measure- ments are expressed in µEinstein in the range 0÷20,000 µE m -2•s-1.

Photosynthetically Active Radiation, PAR. Flow of photons in the wave- length 400÷700 nm.

Photosynthetic photon flux density, PPRD. The number of photons per time unit and air unit in the wavelength 400÷700 nm.

The measurement is expressed in micromoles per second and per square metre. One mole is the equivalent of 6,0222•1023 photons.

Correction filter according to the cosine law.

Typical applications of the probe are for research in the field of greenhouse lighting, research in undergrowth, etc.

– 43 –

Image 21
Contents Instructions Manual 22 23 24 Quantum Photo Radiometer MAN key for choosing the working scale manually Input B socket, DIN 8-pole connectorKey for activating the display of input a Key for activating the display of input BLx/fcd Ding in C or FCount of the time elapsed Shes DataAutomatic Is being taken Seconds, minutes or hoursIf a high value is to be set DisabledThreshold this key is used to Decrease the set valueErr HOW to MeasureOFL Probe ConnectionMethod of USE LOW Battery Warning Serial Output MaintenanceData bit length Start bit Stop bit no parityAD RS 232C Analog OutputBlock Diagram Layout of Components Series HD 9021 Probe Calibration Calibrating the Instrument HDCharacteristics Technical FeaturesMeasurements and measuring ranges Display LCD 12 mm, function and photo-radiometric symbols Start bit Stop bit No parityOver ±0.3% ± 1C ±1 digit Order Code CorrectionSer for cosine correction Typical response curve of the probe is as follows ProbesHD 9021 RAD/PAR HD 9021 RAD/CTypical response curve of the probe is as follows Black light in the field Producing erythematous action in the fieldHD 9021 UVA Producing bactericide germicide action in the fieldHD 9021 UVC HD 9021 UVBLight flux HD 9021/CdLux lx Nit nitSafety EN61000-4-2, EN61010-1 levelVoltage variations