Mustang Survival MSV971 manual Donning and Packing Instructions

Page 15

Mustang Survival MSV971 Life Preserver and Survival Vest

Description and Maintenance Instructions

9 June 2004, Rev: 1.0

3.0DONNING AND PACKING INSTRUCTIONS

3.1GENERAL

WARNING: The MSV971 must be worn fully assembled. The modules are not to be worn separately. A loss of protection and wear resistance may result if worn improperly.

3.2FOLDING AND PACKING INSTRUCTIONS

3.2.1To fold and pack the MSV971:

NOTE: Points of reference (in this section) for folding and packing are based from the perspective of person facing the front of an LP/SV.

a.Remove the zipper closing sliders from inside the inner front pockets of the survival vest.

Figure 8. Step a. Folding and Packing Instructions

Zipper Slider

12

This document is for information purposes only. It is not a controlled

 

document and may not be considered current when printed.

Image 15
Contents June 9, 2004, REV Table of Contents Vest Sizes Table of FiguresIntroduction 5 Fit TestingAssembled LP/SV FeaturesDesign and Construction GeneralInflatable Cell Life PreserverDocument and may not be considered current when printed Beaded CO2 Inflation Handle Manual CO2 Inflation DeviceProtective Container Oral InflatorGrommet Survival VestAdjustable Waist Belt Side Adjustment StrapsRescue Harness System Operation Ballistic Liner Attachment PointsComponent Locations Inflated Cell General Folding and Packing Instructions Donning and Packing InstructionsPosition Zipper ClosingSliders Step f. Folding and Packing Instructions Harness Loop Step j. Folding and Packing Instructions Step o. Folding and Packing Instructions Fresh Water Immersion Maintenance and CareCleaning Treatment After ImmersionStorage Service LifeMaintenance Reporting Work AreaVisual Inspection Inspection and TestingRequirements PRE-FLIGHT and POST-FLIGHT InspectionVisual Inspection of the Inflatable Cell Maintenance InspectionInflation Manifold Valve Test Oral Inflator Valve TestInflatable Cell Test CO2 Inflation Device Test CO2 Cylinder Inspection and Weight TestSewing RepairsIdentification of Defects Survival Vest or Protective ContainerDamage Treatment Repair MaterialsProtective Container Fabric Patching Step b. Patching Steps f. and g. Patching 12 mm 1/2 CO2 Inflation Device Oral Inflator ValveStep a. Replace Inflatable Cell Self-locking Tie CO2 Cylinder Step g. Replace Inflatable Cell Self-locking TieSummary Parts ListMSV971 Survival Vest and Index Numbers Parts List for the MSV971 Survival Vest MM Solas Reflective Tape MSV971 Inflatable Cell and Index Numbers MSV971 Protective Cover and Index Numbers