2.5MANUAL CO2 INFLATION DEVICE

The MSV971 is an appropriate platform for a wide variety of customized LP/SV units to address user requirements that include:

use in ejection seat fitted aircraft

use with an automation inflation device

stowage of unique pieces/combinations of survival equipment Contact Mustang Survival for further details.

2.5.1Life preservers, which are intended for use in non-ejection seat, equipped aircraft incorporate a manually operated inflation device. The operating components of the manual inflation device (Halkey-Roberts HD77189 840 AMLS INFLATOR) are shown in figure 5.

Figure 5. Manual CO2 Inflation Device – Non-Operated/Ready Position

CO2 Cylinder

Manual Inflator

Lever in Up and

Ready Position

Green Indicator Pin

Pull-tab

2.5.2The manual inflation device is located on the rear left lobe of the inflatable cell. The inflation device is secured with a cap nut to the manifold valve, which in turn is RF bonded to the inflatable cell. A 34-37 gram carbon dioxide (CO2) cylinder is threaded into the top of the inflation device, and is secured against the cell with a looped nylon elastic retaining strap. The beaded inflation handle is attached with a lanyard to the operating lever of the inflation device, which in turn is safety tied by inserting and tying a red cotton witness thread through the hole in the operating lever and through the hole in the body of the inflation device.

2.6BEADED CO2 INFLATION HANDLE

2.6.1The beaded inflation handle is constructed of six plastic beads threaded onto a loop of nylon webbing. The handle is attached with a lanyard to the operating lever of the CO2 inflation device and is fixed with Velcro™ to the back side of the left lobe of the protective container.

6

This document is for information purposes only. It is not a controlled

 

document and may not be considered current when printed.

Image 9
Contents June 9, 2004, REV Table of Contents Vest Sizes Table of FiguresIntroduction 5 Fit Testing Design and Construction Features General Assembled LP/SVInflatable Cell Life PreserverDocument and may not be considered current when printed Beaded CO2 Inflation Handle Manual CO2 Inflation DeviceProtective Container Oral InflatorGrommet Survival VestAdjustable Waist Belt Side Adjustment StrapsRescue Harness System Operation Ballistic Liner Attachment PointsComponent Locations Inflated Cell General Folding and Packing Instructions Donning and Packing InstructionsPosition Zipper ClosingSliders Step f. Folding and Packing Instructions Harness Loop Step j. Folding and Packing Instructions Step o. Folding and Packing Instructions Cleaning Maintenance and CareTreatment After Immersion Fresh Water ImmersionMaintenance Reporting Service LifeWork Area StorageRequirements Inspection and TestingPRE-FLIGHT and POST-FLIGHT Inspection Visual InspectionVisual Inspection of the Inflatable Cell Maintenance InspectionInflation Manifold Valve Test Oral Inflator Valve TestInflatable Cell Test CO2 Inflation Device Test CO2 Cylinder Inspection and Weight TestIdentification of Defects RepairsSurvival Vest or Protective Container SewingDamage Treatment Repair MaterialsProtective Container Fabric Patching Step b. Patching Steps f. and g. Patching 12 mm 1/2 CO2 Inflation Device Oral Inflator ValveStep a. Replace Inflatable Cell Self-locking Tie CO2 Cylinder Step g. Replace Inflatable Cell Self-locking TieSummary Parts ListMSV971 Survival Vest and Index Numbers Parts List for the MSV971 Survival Vest MM Solas Reflective Tape MSV971 Inflatable Cell and Index Numbers MSV971 Protective Cover and Index Numbers