Mustang Survival MSV971 manual Visual Inspection of the Inflatable Cell, Maintenance Inspection

Page 23

Mustang Survival MSV971 Life Preserver and Survival Vest

Description and Maintenance Instructions

9 June 2004, Rev: 1.0

5.3.4Visual Inspection of the Inflatable Cell

5.3.4.1A visual inspection of the inflatable cell should consist of the following:

a.Open the protective cover by separating the Velcro™ tab at the rear and pulling the zipper halves apart.

b.Ensure the life preserver inflatable cell is properly secured to the protective container, with self-locking tie intact.

c.Check the cell for physical damage and excessive wear, e.g., abrasion, holes, cuts, tears or checking. If any damage is found, the cell must be replaced.

d.Check for condition of all Radio Frequency (RF) seams and bonding. If any damage is found (i.e. bubbling or burns in fabric, breaks, cuts or tears on weld), the cell must be replaced.

e.Check for security of both oral inflators and that the back oral inflation valve is in the locked closed position and the front oral inflation valve is in the locked open position.

f.Check for security of all grommets, anchor patch assemblies, and retaining patch assemblies. If any damage is found, the cell must be replaced.

g.Remove the CO2 cylinder and ensure the cylinder has not been fired or cylinder pierced.

h.Check for security and correct installation of the CO2 inflation device.

i.Check for damage to the internal CO2 cylinder mating threads. If any damage is found, the device must be replaced.

j.Ensure the beaded CO2 inflation handle is properly attached to the operating lever of the CO2 inflation device. Note any fraying at the attachment point and replace it if necessary.

k.Ensuring that the cylinder seat-sealing gasket is correctly positioned, replace the cylinder and ensure that the witness thread or wire on the CO2 inflation device is intact.

l.Ensure both rescue harnesses are intact and properly stored within the life preserver protective container and that the buddy-line and whistle are intact and properly stored on the right harness. Ensure the rescue harnesses is properly routed.

m.Refold the inflatable cell and secure it within the protective container (see section 3.2 – Folding and Packing).

5.4MAINTENANCE INSPECTION

5.4.1Have qualified safety systems personnel perform the maintenance inspection, an in-depth inspection, in accordance with this manual.

5.4.2Perform the following tests and inspections, forming the overall maintenance inspection, in this order:

a.Remove the inflatable cell from the protective container.

b.Perform the inflation manifold valve test as per section 5.5.

c.Perform the oral inflator valve test as per section 5.6.

d.Perform the inflatable cell test as per section 5.7.

20

This document is for information purposes only. It is not a controlled

 

document and may not be considered current when printed.

Image 23
Contents June 9, 2004, REV Table of Contents Vest Sizes Table of FiguresIntroduction 5 Fit TestingAssembled LP/SV FeaturesDesign and Construction GeneralInflatable Cell Life PreserverDocument and may not be considered current when printed Beaded CO2 Inflation Handle Manual CO2 Inflation DeviceProtective Container Oral InflatorGrommet Survival VestRescue Harness System Adjustable Waist BeltSide Adjustment Straps Operation Ballistic Liner Attachment PointsComponent Locations Inflated Cell General Folding and Packing Instructions Donning and Packing InstructionsSliders PositionZipper Closing Step f. Folding and Packing Instructions Harness Loop Step j. Folding and Packing Instructions Step o. Folding and Packing Instructions Fresh Water Immersion Maintenance and Care Cleaning Treatment After ImmersionStorage Service LifeMaintenance Reporting Work AreaVisual Inspection Inspection and TestingRequirements PRE-FLIGHT and POST-FLIGHT InspectionVisual Inspection of the Inflatable Cell Maintenance InspectionInflatable Cell Test Inflation Manifold Valve TestOral Inflator Valve Test CO2 Inflation Device Test CO2 Cylinder Inspection and Weight TestSewing RepairsIdentification of Defects Survival Vest or Protective ContainerProtective Container Fabric Patching Damage TreatmentRepair Materials Step b. Patching Steps f. and g. Patching 12 mm 1/2 CO2 Inflation Device Oral Inflator ValveStep a. Replace Inflatable Cell Self-locking Tie CO2 Cylinder Step g. Replace Inflatable Cell Self-locking TieSummary Parts ListMSV971 Survival Vest and Index Numbers Parts List for the MSV971 Survival Vest MM Solas Reflective Tape MSV971 Inflatable Cell and Index Numbers MSV971 Protective Cover and Index Numbers