Mustang Survival MSV971 manual Ballistic Liner Attachment Points, Operation

Page 13

Mustang Survival MSV971 Life Preserver and Survival Vest

Description and Maintenance Instructions

9 June 2004, Rev: 1.0

2.13BALLISTIC LINER ATTACHMENT POINTS

2.13.1The MSV971 has built-in provisions for adding an optional ballistic liner accessory to the inside of the survival vest. The vest has two zippers running along the inside of the main opening and a Velcro™ tab at the inner neck that secure the ballistic liner.

NOTE: Depending on the thickness of the liner used, switching to a larger sized survival vest may be necessary when worn with a ballistic liner.

2.14OPERATION

CAUTION: Over-pressurization will over-stress the inflatable cell. Both chambers of the cell must be completely evacuated of any residual air or carbon dioxide gas prior to CO2 inflation.

2.14.1Manual operation of the life preserver is accomplished by grasping the beaded inflation handle located on the lower left side of the protective container. Jerking sharply downwards rotates the operating lever of the CO2 inflation device, which in turn forces the piercing pin to puncture the neck of the CO2 cylinder and allow the compressed gas to flow into the inflatable cell.

The MSV971 is an appropriate platform for a wide variety of customized LP/SV units to address user requirements that include:

use in ejection seat fitted aircraft

use with an automation inflation device

stowage of unique pieces/combinations of survival equipment Contact Mustang Survival for further details.

10

This document is for information purposes only. It is not a controlled

 

document and may not be considered current when printed.

Image 13
Contents June 9, 2004, REV Table of Contents Vest Sizes Table of FiguresIntroduction 5 Fit TestingDesign and Construction FeaturesGeneral Assembled LP/SVInflatable Cell Life PreserverDocument and may not be considered current when printed Beaded CO2 Inflation Handle Manual CO2 Inflation DeviceProtective Container Oral InflatorGrommet Survival VestSide Adjustment Straps Adjustable Waist BeltRescue Harness System Operation Ballistic Liner Attachment PointsComponent Locations Inflated Cell General Folding and Packing Instructions Donning and Packing InstructionsZipper Closing PositionSliders Step f. Folding and Packing Instructions Harness Loop Step j. Folding and Packing Instructions Step o. Folding and Packing Instructions Cleaning Maintenance and CareTreatment After Immersion Fresh Water ImmersionMaintenance Reporting Service LifeWork Area StorageRequirements Inspection and TestingPRE-FLIGHT and POST-FLIGHT Inspection Visual InspectionVisual Inspection of the Inflatable Cell Maintenance InspectionOral Inflator Valve Test Inflation Manifold Valve TestInflatable Cell Test CO2 Inflation Device Test CO2 Cylinder Inspection and Weight TestIdentification of Defects RepairsSurvival Vest or Protective Container SewingRepair Materials Damage TreatmentProtective Container Fabric Patching Step b. Patching Steps f. and g. Patching 12 mm 1/2 CO2 Inflation Device Oral Inflator ValveStep a. Replace Inflatable Cell Self-locking Tie CO2 Cylinder Step g. Replace Inflatable Cell Self-locking TieSummary Parts ListMSV971 Survival Vest and Index Numbers Parts List for the MSV971 Survival Vest MM Solas Reflective Tape MSV971 Inflatable Cell and Index Numbers MSV971 Protective Cover and Index Numbers