Mustang Survival MD3196, MD3091 manual Testing for Leaks, Testing the Oral Inflation Valve

Page 17

LP is free of rips, tears, or holes

LP seams are securely sewn

LP fabric, straps, and hardware are free from any defects

Perform the following tests every 180 days, or more frequently if exposed to potential damage or used in extreme conditions.

Testing for Leaks

1.Orally inflate the LP until it is firm to the touch, and let it stand for two hours—a leaking LP will not hold its firmness.

2.If the LP is leaking, take it to a service department for evaluation and/ or servicing.

Testing the Oral Inflation Valve

1.Fully inflate the LP using the oral inflator, then hold the valve under water.

2.If bubbles appear, deflate and retest. If the leak persists, take the LP to a Mustang dealer for evaluation and/or servicing.

CAUTION: To avoid accidental inflation, do not allow water to contact the hydrostatic inflator.

General Tests and Inspections

Record the following tests in permanent ink in the Date Maintained column on the Care and Storage label.

After each test or inspection, repack the LP – see Repacking.

Perform the following tests and inspections annually, after each inflation, or whenever the integrity of the LP is in doubt.

Visually inspect all components for dirt or corrosion, and clean or replace as necessary – see Readiness Checklist.

Visually inspect the LP for damage or excessive abrasion, wear, fabric tears, or contamination. Particular attention must be paid to the stitching, straps, and hardware.

Test for leaks.

Test the oral inflation valve.

On the MD3196, ensure the inflator expiry date has not passed. If it has, replace the inflator – see Re-arming.

Ensure the status indicator is green – see Product Familiarization.

14

 

Compact Tactical LP Owners Manual

Image 17
Contents MD3196 & MD3091 Do not Remove Prior to Sale Contents Introduction MD3196 Product Familiarization and ReadinessPrior to Use Readiness Checklist MD3196 & MD3091MD3091 Inflating WearingManual Inflation Auto-Inflation MD3196Oral Inflation DeflatingRE-ARMING the MD3196 RE-ARMING the MD3091 Folding RepackingStowing the Manual Conversion Cap MD3196 Only Closing Zipper 1 Long ZipperClosing Zipper 2 Short Zipper Integrating Pouch Attachment Ladder System and Molle Vest Attaching the MA3090 Harness Quick-Release FeaturesAUTO/MANUAL Conversion Reversing the Conversion Care and MaintenanceGeneral Tests and Inspections Testing for LeaksTesting the Oral Inflation Valve Testing the Automatic Inflator Testing the Manual InflatorAccessories Cleaning and StorageHT1144 Rev Feb2012