Mustang Survival MD3196 manual RE-ARMING the MD3091

Page 10

10.While pressing firmly onto the inflator body, turn the black locking ring clockwise to the locked position, and pull on the inflator cap to ensure

it is locked onto the inflator body (Figure 14).

11.Ensure that the status indicator on the new inflator cap is green, the pull- to-inflate lanyard is present, and the locking ring is locked.

FIGURE 14

Hydrostatic Water

 

Inlet Valve

 

Black Locking Ring

 

Tabs

Status

Manual In￿ation

Indicator

Lanyard

Expiry Date

 

12.To test for leakage, inflate the LP

using the oral inflator tube – see Inflating. To avoid damage to the LP do not use a compressor (the maximum pressure should not exceed 2 psi). After two hours there should be no noticeable drop in pressure in the LP.

13.Deflate and repack the LP – see Deflating, and Repacking.

RE-ARMING THE MD3091

CAUTION: The LP must be deflated before being re-armed.

NOTE: An MA7170 re-arming kit is required for this procedure.

CAUTION: Follow the steps below in the exact sequence described.

1.Unscrew and discard the CO2 cylinder (Figure 15).

2.Ensure the manual lever is in the up and ready position and the manual inflator mechanism status pin is properly

installed. If missing or damaged, replace the

 

status pin (Figure 15).

CO2 Cylinder

3. To install the new CO2 cylinder, screw it into

In￿ator Mechanism

 

the top of the inflator and hand-tighten. To

Up-and-Ready

avoid damage to the internal gasket, do not

Status Pin

over-tighten (Figure 15).

In￿ation Lanyard

 

4. To test for leakage, inflate the LP using the

Beaded Manual

oral inflator tube – see Inflating. To avoid

In￿ation Handle

FIGURE 15

damage to the LP do not use a compressor

 

(the maximum pressure should not exceed

 

2 psi). After two hours there should be no

 

noticeable drop in pressure in the LP.

 

5.Deflate and repack the LP – see Deflating, and Repacking.

7

 

Compact Tactical LP Owners Manual

Image 10
Contents MD3196 & MD3091 Do not Remove Prior to Sale Contents Introduction Product Familiarization and Readiness MD3196MD3091 Readiness Checklist MD3196 & MD3091Prior to Use Manual Inflation WearingInflating Auto-Inflation MD3196Deflating Oral InflationRE-ARMING the MD3196 RE-ARMING the MD3091 Repacking FoldingClosing Zipper 2 Short Zipper Closing Zipper 1 Long ZipperStowing the Manual Conversion Cap MD3196 Only Integrating Pouch Attachment Ladder System and Molle Vest Quick-Release Features Attaching the MA3090 HarnessAUTO/MANUAL Conversion Care and Maintenance Reversing the ConversionTesting the Oral Inflation Valve Testing for LeaksGeneral Tests and Inspections Testing the Manual Inflator Testing the Automatic InflatorCleaning and Storage AccessoriesHT1144 Rev Feb2012