Mustang Survival manual Readiness Checklist MD3196 & MD3091, Prior to Use

Page 6

MD3091

The left lobe (as worn) of the MD3091 LP contains the oral inflator tube assembly-A. The right lobe of the LP contains the manual inflator assembly-B and the orange whistle-C. .

To become more familiar with the LP components:

1.Open both zippers completely, and place the LP on a smooth, flat surface with the inflator facing the user.

2.Ensure the oral inflator dust cap is in the stowed position.

3.Ensure the status pin and the CO2 cylinder are intact, and the lever is in the up and ready position (Figure 6).

4.If the cylinder is not intact, and/or if the status pin is missing or broken, re-arm the cylinder and replace the status pin – see Re-arming (Figure 7).

5.Repack the LP – see Repacking.

Prior to Use

Visually inspect the LP prior to use to:

FIGURE 5

C A

B

FIGURE 6

CO2 Cylinder

In￿ator Mechanism

Up-and-Ready

Status Pin

In￿ation Lanyard

Beaded Manual

In￿ation Handle

FIGURE 7

Piercing Pin Status Pin

Inflation Lever

ensure the LP is properly armed

ensure the LP is free of rips, tears, or holes and all seams are securely sewn

ensure the fabric, straps, and hardware are free from any defects

READINESS CHECKLIST (MD3196 & MD3091)

When all applicable boxes are checked, the LP is ready for use: FF Beaded manual inflation handle is fastened.

FF No rips, tears, or holes, and all seams securely sewn. FF Fabric, straps, and hardware free from defects.

FF All zippers, Velcro™, and chest buckle securely fastened. FF MD3196 only: Status indicator is green.

FF MD3196 only: Inflator expiry date has not passed.

FF MD3091 only: Status pin and cylinder intact, and manual inflation lever in the up and ready position.

NOTE: If there are any concerns about the readiness of the MD3196 or MD3091, contact the Mustang Survival dealer.

3

 

Compact Tactical LP Owners Manual

Image 6
Contents MD3196 & MD3091 Do not Remove Prior to Sale Contents Introduction Product Familiarization and Readiness MD3196Readiness Checklist MD3196 & MD3091 MD3091Prior to Use Manual Inflation WearingInflating Auto-Inflation MD3196Deflating Oral InflationRE-ARMING the MD3196 RE-ARMING the MD3091 Repacking FoldingClosing Zipper 1 Long Zipper Closing Zipper 2 Short ZipperStowing the Manual Conversion Cap MD3196 Only Integrating Pouch Attachment Ladder System and Molle Vest Quick-Release Features Attaching the MA3090 HarnessAUTO/MANUAL Conversion Care and Maintenance Reversing the ConversionTesting for Leaks Testing the Oral Inflation ValveGeneral Tests and Inspections Testing the Manual Inflator Testing the Automatic InflatorCleaning and Storage AccessoriesHT1144 Rev Feb2012