Mustang Survival MD3091 manual RE-ARMING the MD3196

Page 9

RE-ARMING THE MD3196

CAUTION: The LP must be deflated before being re-armed.

NOTE: An MA7214-10 re-arming kit is required for this procedure.

1. Open both

FIGURE 9

zippers, wipe

off any water,

 

and place the

 

LP on a smooth,

 

flat surface with

 

the inflator

 

facing the user.

 

2.Reach under

the cover and carefully pull the manual/ automatic inflator assembly out from under the cover fabric.

3.Hold the CO2 cylinder through the fabric, insert the metal key between the black locking ring and inflator cap, and turn the key counter-clockwise (Figure 9).

4.Turn the black locking ring counter- clockwise, and lift off (and discard) the yellow inflator cap (Figure 10).

5.Elongate the sealing ring by squeezing it, and remove (and discard) the inflator body through the ring (Figure 11).

6.Visually Inspect the sealing ring for cracks, debris, or other damage. If damage is present, remove the LP from active service for further assessment.

FIGURE 10

FIGURE 11

Center

Shaft

Status

Indicator

Sealing

Ring

FIGURE 12

Center

Shaft

Status

Indicator

Sealing

Ring

7.Ensure that the status indicator on the new inflator body is green, and the expiry date has not passed (Figure 12). If the status indicator is red, or the expiry date has passed, acquire a new inflator body.

CAUTION: Do not turn the small center shaft of the inflator body.

8.Insert the new inflator body, with the CO2 cylinder pointing upward, inside the LP (Figure 12), and let the sealing ring rest on the adapter around the four lugs.

9.Hold the CO2 cylinder through the fabric of the LP, and position the new inflator cap with the valve pointing to the right ensuring the cap is properly seated on the inflator body and sealing ring (Figure 13).

FIGURE 13

6

Compact Tactical LP Owners Manual

Image 9
Contents MD3196 & MD3091 Do not Remove Prior to Sale Contents Introduction MD3196 Product Familiarization and Readiness Readiness Checklist MD3196 & MD3091 MD3091 Prior to Use Inflating WearingManual Inflation Auto-Inflation MD3196Oral Inflation DeflatingRE-ARMING the MD3196 RE-ARMING the MD3091 Folding RepackingClosing Zipper 1 Long Zipper Closing Zipper 2 Short ZipperStowing the Manual Conversion Cap MD3196 Only Integrating Pouch Attachment Ladder System and Molle Vest Attaching the MA3090 Harness Quick-Release FeaturesAUTO/MANUAL Conversion Reversing the Conversion Care and MaintenanceTesting for Leaks Testing the Oral Inflation ValveGeneral Tests and Inspections Testing the Automatic Inflator Testing the Manual InflatorAccessories Cleaning and StorageHT1144 Rev Feb2012