Mustang Survival MD3091, MD3196 manual Deflating, Oral Inflation

Page 8

Oral Inflation

A properly armed LP will inflate correctly. However, when top-up inflation, or total inflation in a non-emergency situation is required, the LP can be inflated by mouth.

When fully inflated automatically the carbon dioxide (CO2 gas) used to auto-inflate the LP slowly escapes through the fabric over time. A slight reduction of pressure is apparent several hours after inflation. Therefore, oral top-up inflation may be required during prolonged immersion. To orally inflate the LP:

1.Disengage both zippers completely and open the left lobe of the LP.

2.Locate the oral inflator tube, and remove the dust cap from the end of the tube.

3.Blow into the tube until the LP is fully inflated.

4.Replace the dust cap in the stowed position.

DEFLATING

CAUTION: Deflating the LP by any means other than by inverting the oral inflator dust cap may damage the oral inflator valve.

1.To deflate the LP, remove the oral inflator

dust cap from the oral inflator tube, reverse the dust cap and reinsert it into the tube. The dust cap does not lock and must be held in place (Figure 8).

2. Gently squeeze the LP until fully deflated,

ensuring all air or gas is removed from the

 

LP. To avoid damage, do not wring or twist

FIGURE 8

the LP or the cell.

 

3.Replace the dust cap in the stowed position.

4.Visually inspect the inflator status. The status indicator on the MD3196 LP must be green, and the status pin on the MD3091 LP must be in place before repacking the LP. If those conditions are not met, the LP inflator has been fired and must be re-armed – see Re-arming.

5.Repack the LP – see Repacking.

5

 

Compact Tactical LP Owners Manual

Image 8
Contents MD3196 & MD3091 Do not Remove Prior to Sale Contents Introduction Product Familiarization and Readiness MD3196Prior to Use Readiness Checklist MD3196 & MD3091MD3091 Wearing InflatingManual Inflation Auto-Inflation MD3196Deflating Oral InflationRE-ARMING the MD3196 RE-ARMING the MD3091 Repacking FoldingStowing the Manual Conversion Cap MD3196 Only Closing Zipper 1 Long ZipperClosing Zipper 2 Short Zipper Integrating Pouch Attachment Ladder System and Molle Vest Quick-Release Features Attaching the MA3090 HarnessAUTO/MANUAL Conversion Care and Maintenance Reversing the ConversionGeneral Tests and Inspections Testing for LeaksTesting the Oral Inflation Valve Testing the Manual Inflator Testing the Automatic InflatorCleaning and Storage AccessoriesHT1144 Rev Feb2012