Mustang Survival MD3085, MD3087 manual HOW do YOU Test Your PFD Using the Oral INFLATOR?

Page 21

HOW DO YOU TEST YOUR PFD USING THE MANUAL INFLATOR?

1)To test your Inflatable PFD, you will need your fully armed Inflatable PFD, and re-arming kit approved for your Inflatable PFD: MA7203 for model MD3085, MA7202 for model MD3087.

2)Put on the Inflatable PFD.

3)Actuate the inflation system by jerking firmly downward on the pull-tab. The Inflatable PFD should fully inflate within 5 seconds.

4)Get into shallow water, just deep enough that you can stand with your head above the surface.

5)See if the Inflatable PFD will float you on your back or just slightly back of vertical. In a relaxed floating position, verify that your mouth is well above the water’s surface. Note the effect of where you hold your legs and how you float.

6)Get out of the water and remove the Inflatable PFD. Completely deflate the Inflatable PFD using the oral inflator (see Deflating the

Inflatable PFD p. 7). Remove the CO2 cylinder/bayonet assembly from the inflator.

7)Let the Inflatable PFD dry thoroughly. Re-arm and Repack the PFD (p. 13).

HOW DO YOU TEST YOUR PFD USING THE ORAL INFLATOR?

1)No spare parts or re-arming kits are needed to test your Inflatable PFD.

2)Remove the CO2 cylinder/bayonet assembly to prevent inadvertent inflation, which could potentially damage the Inflatable PFD. Inspect the cylinder to confirm it is unused (Fig. 10). Unscrew and remove the cap and the bobbin (MD3087 only). Otherwise the bobbin will disintegrate during water immersion.

3)Put on the Inflatable PFD.

4)Get into shallow water, just deep enough that you can stand with your head above the surface.

19

Inflatable PFD Owner’s Manual

Image 21
Contents MD3085 Inflatable PFD Contents Approval Conditions and Carriage Requirements Instructions for USE What is AN Inflatable PFD?Component Inspection Instructions Uninspected Commercial Vessel UseReadiness Checklist Donning InstructionsSizing and Fit Manual Inflation Inflating Your Inflatable PFDAutomatic Backup Inflation MD3087 InformationOral Inflation Deflating the Inflatable PFD Special Considerations for Automatic Devices MD3087Usage Below Freezing Re-arming Your PFD MD3085Important Follow instructions in the exact sequence below MD3085 Manual Inflator Re-arming Your PFD MD3087 Removed prior to re-arming MD3087 Automatic InflatorTop Repacking Care and Maintenance Instructions Is Your PFD in Good and Serviceable CONDITION?Every Two 2 Months Before Each UseCleaning and Storing of Your Inflatable PFD MD3085 HOW and WHY to Test Your PFD Cleaning and Storing of Your Inflatable PFD MD3087Put on the Inflatable PFD Model MD3087HOW do YOU Test Your PFD Using the Manual INFLATOR? HOW do YOU Test Your PFD Using the Oral INFLATOR?Hypothermia Wear Your PFDOver How hypothermia affects most adultsInflatable PFD Safety Accessories Do not Attach PFD’S to Your Boat Additional InformationWE Save Lives for a Living