Mustang Survival MD3085 manual Model MD3087, Put on the Inflatable PFD

Page 20

MODEL MD3087

The U.S.Coast Guard recommends that you purchase two automatic re-arming kits (MA7202). One kit is to be used immediately in testing the automatic inflation system (see HOW DO YOU TEST YOUR PFD USING THE AUTOMATIC INFLATOR?, p. 18) and the other to carry on board as a spare.

The U.S. Coast Guard recommends you test the automatic inflation system in the water at the beginning of each boating season. By doing this, you demonstrate that the automatic inflation system is still working properly and reduce the likelihood of premature inflation and its associated dangers.

HOW DO YOU TEST YOUR PFD USING THE AUTOMATIC INFLATOR? (MD3087)

1)To test your Inflatable PFD, you will need your fully armed Inflatable PFD, and re-arming kit (MA7202) approved for your Inflatable PFD

2)Put on the Inflatable PFD.

3)Get into shallow water, just deep enough that you can stand with your head above the surface. Once the inflator is underwater the Inflatable PFD should fully inflate automatically within 10 seconds.

4)See if the Inflatable PFD will float you on your back or just slightly back of vertical. In a relaxed floating position, verify that your mouth is well above the water’s surface. Note the effect of where you hold your legs on how you float.

5)Get out of the water and remove the Inflatable PFD. Remove the

used CO2 cylinder/bayonet assembly and the used bobbin from the Inflatable PFD inflator.

Deflate the Inflatable PFD by depressing the oral inflator valve (see Deflating the Inflatable PFD p. 7).

6)Let the Inflatable PFD dry thoroughly. Re-arm and Repack the PFD (p. 13).

Inflatable PFD Owner’s Manual

18

Image 20
Contents MD3085 Inflatable PFD Contents Approval Conditions and Carriage Requirements What is AN Inflatable PFD? Instructions for USEUninspected Commercial Vessel Use Component Inspection InstructionsSizing and Fit Readiness ChecklistDonning Instructions Inflating Your Inflatable PFD Manual InflationOral Inflation Automatic Backup Inflation MD3087Information Special Considerations for Automatic Devices MD3087 Deflating the Inflatable PFDImportant Follow instructions in the exact sequence below Usage Below FreezingRe-arming Your PFD MD3085 MD3085 Manual Inflator Re-arming Your PFD MD3087 MD3087 Automatic Inflator Removed prior to re-armingTop Repacking Is Your PFD in Good and Serviceable CONDITION? Care and Maintenance InstructionsBefore Each Use Every Two 2 MonthsCleaning and Storing of Your Inflatable PFD MD3085 Cleaning and Storing of Your Inflatable PFD MD3087 HOW and WHY to Test Your PFDModel MD3087 Put on the Inflatable PFDHOW do YOU Test Your PFD Using the Oral INFLATOR? HOW do YOU Test Your PFD Using the Manual INFLATOR?Wear Your PFD HypothermiaHow hypothermia affects most adults OverInflatable PFD Safety Accessories Additional Information Do not Attach PFD’S to Your BoatWE Save Lives for a Living