Mustang Survival MD3087, MD3085 manual Is Your PFD in Good and Serviceable CONDITION?

Page 16

15 depicts a correctly folded Inflatable PFD.

NOTE: Ensure that all Velcro™ strips and tabs are fastened.

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

F

 

F

A

B

D

C

 

 

 

 

 

 

FIGURE 12

A

B

D

C

FIGURE 14

 

 

 

 

 

 

 

 

 

FIGURE 13

 

 

 

FIGURE 15

Pull-tab

IS YOUR PFD IN GOOD AND SERVICEABLE CONDITION?

Check your Inflatable PFD between outings to be sure that it is properly armed; that it is free of rips, tears or holes; that all seams are securely sewn; and that the fabric, straps and hardware are still strong (See Readiness Checklist, p. 4). Inspect the inflatable portion of the Inflatable PFD in accordance with the CARE AND MAINTENANCE INSTRUCTIONS.

CARE AND MAINTENANCE INSTRUCTIONS

Federal Regulations require Coast Guard approved personal flotation devices (PFDs) that are legibly marked with the Coast Guard approval number, are in good and serviceable condition, and are the correct size for each person on board. It is the responsibility of the operator to be sure this PFD is in serviceable condition. To be considered serviceable, this PFD shall not exhibit deterioration that could diminish its performance, such as broken or deformed hardware, detached webbing, rotted structural components, air leaks or nonfunctional inflators. Unless worn inflated, this PFD must also be properly armed with a cylinder installed in the inflator, and service indicator showing green. See Page 2

Inflatable PFD Owner’s Manual

14

Image 16
Contents MD3085 Inflatable PFD Contents Approval Conditions and Carriage Requirements What is AN Inflatable PFD? Instructions for USEUninspected Commercial Vessel Use Component Inspection InstructionsDonning Instructions Readiness ChecklistSizing and Fit Inflating Your Inflatable PFD Manual InflationInformation Automatic Backup Inflation MD3087Oral Inflation Special Considerations for Automatic Devices MD3087 Deflating the Inflatable PFDRe-arming Your PFD MD3085 Usage Below FreezingImportant Follow instructions in the exact sequence below MD3085 Manual Inflator Re-arming Your PFD MD3087 MD3087 Automatic Inflator Removed prior to re-armingTop Repacking Is Your PFD in Good and Serviceable CONDITION? Care and Maintenance InstructionsBefore Each Use Every Two 2 MonthsCleaning and Storing of Your Inflatable PFD MD3085 Cleaning and Storing of Your Inflatable PFD MD3087 HOW and WHY to Test Your PFDModel MD3087 Put on the Inflatable PFDHOW do YOU Test Your PFD Using the Oral INFLATOR? HOW do YOU Test Your PFD Using the Manual INFLATOR?Wear Your PFD HypothermiaHow hypothermia affects most adults OverInflatable PFD Safety Accessories Additional Information Do not Attach PFD’S to Your BoatWE Save Lives for a Living