6)Inspect the bobbin. If the bobbin has been fired or damaged, replace it! Ensure the new bobbin is valid, it must have been purchased within the last three (3) years. If the bobbin purchase date is unknown, check the date printed on the bobbin and replace if older than three (3) years (see Re-arming Your PFD (MD3087), p. 10).

7)IMPORTANT! Bobbin (yellow) must be installed into the HOUSING (**see figure 9), white side up, aligning the slots on the bobbin with the ridges inside the threaded housing. The bobbin will slide in easily if installed correctly.

8)Install cap by screwing clockwise until it meets the housing shoulder.

9)Check the new cylinder/bayonet assembly to ensure the o-ring is in

place and the sensor ring is attached (Fig. 9). Ensure that the CO2 cylinder has not been pierced (Fig. 10).

FIGURE 10

 

Solid

Pierced

Cylinder

Cylinder

Top

Top

Attached

Broken

Sensor

Sensor

Ring

Ring

Caution: Do not use the cylinder/bayonet assembly if either the o-ring or sensor ring is broken, missing or damaged.

IMPORTANT: You will damage the sensor ring if bobbin and cap are not installed first.

10)Push, and hold, the lever into the inflator housing. The pull-cord should be situated in the groove (Fig. 11). Install a new cylinder/ bayonet assembly by engaging bayonet tabs in housing, pushing in then turning clockwise 1/8 turn to a full stop (Fig. 11).

WARNING: PFD WILL ONLY INFLATE IF CYLINDER IS TURNED TO A FULL STOP.

11)Examine the service indicator (Fig. 9) and ensure it is GREEN. If the service indicator is red, the mechanism has been fired or is incorrectly fitted and the inflator requires service. See

Inflatable PFD Owner’s Manual

12

Image 14
Contents MD3085 Inflatable PFD Contents Approval Conditions and Carriage Requirements What is AN Inflatable PFD? Instructions for USEUninspected Commercial Vessel Use Component Inspection InstructionsSizing and Fit Readiness ChecklistDonning Instructions Inflating Your Inflatable PFD Manual InflationOral Inflation Automatic Backup Inflation MD3087Information Special Considerations for Automatic Devices MD3087 Deflating the Inflatable PFDImportant Follow instructions in the exact sequence below Usage Below FreezingRe-arming Your PFD MD3085 MD3085 Manual Inflator Re-arming Your PFD MD3087 MD3087 Automatic Inflator Removed prior to re-armingTop Repacking Is Your PFD in Good and Serviceable CONDITION? Care and Maintenance InstructionsBefore Each Use Every Two 2 MonthsCleaning and Storing of Your Inflatable PFD MD3085 Cleaning and Storing of Your Inflatable PFD MD3087 HOW and WHY to Test Your PFDModel MD3087 Put on the Inflatable PFDHOW do YOU Test Your PFD Using the Oral INFLATOR? HOW do YOU Test Your PFD Using the Manual INFLATOR?Wear Your PFD HypothermiaHow hypothermia affects most adults OverInflatable PFD Safety Accessories Additional Information Do not Attach PFD’S to Your BoatWE Save Lives for a Living