XI. SUMMARY OF ERROR MESSAGES

XI. SUMMARY OF ERROR MESSAGES

SYSTEM/CONTROL

ERROR

CURRENT

PROBE IS

BAD

CHECK

FOOD

PROBES

 

PLUGGED IN

 

EXIT

CHILLING

AIR:

 

10°F

 

 

 

 

41°F

3

2 37°F

 

 

 

 

 

 

 

STOP/RESET

 

 

FAILED PROBE (#1)

 

SYSTEM/CONTROL

ERROR

CHILL

TIME

EXCEEDED

CONTACT

SERVICE!

 

 

 

 

 

 

EXIT

SYSTEM/CONTROL

ERROR

DEFROST

FAILURE

 

 

CONTACT

SERVICE!

 

 

 

 

 

 

EXIT

SYSTEM/CONTROL

ERROR

NO PRODUCT

PROBES

 

CHECK

FOOD

PROBES

 

USE

BY

TIME

 

EXIT

SYSTEM/CONTROL

ERROR

OVER

TEMPERATURE

 

CONTACT

SERVICE!

 

TURN

OFF/UNPLUG

UNIT

PRODUCT

DETECTED!

 

STARTING

HOLD MODE

CHECK

FOOD

PROBES

 

 

 

 

 

 

EXIT

AIR

TEMP

SENSOR

 

 

NOT

READING

 

 

 

CONTACT

SERVICE

 

 

TURN

OFF/UNPLUG

UNIT

XI. a - FOOD PROBE ERROR DURING CHILL CYCLE BY TEMP:

In the event of a food probe error during a BY TEMP chill cycle, the control automatically switches to a BY TIME chill cycle. The timer will begin to countdown from 90 minutes, at which time the chill cycle will be complete.

XI. b - FOOD PROBE ERROR DURING CHILL CYCLE BY TIME:

In the event of a food probe error during a BY TIME chill cycle, or during a refrigerated holding cycle, the control will no longer display a temperature for that probe.

XI. c - CHILL TIME EXCEEDED:

In the event a chill cycle does not complete within six hours, the control automatically switches operation to a refrigerated holding cycle. This cycle will continue until the operate selects EXIT and returns to the main menu to choose another cycle option.

XI. d - DEFROST FAILURE:

Occurs when either a coil probe temperature falls below 25°F after a de- frost cycle, or in the event of a probe short circuit. Unit automatically switches to IDLE mode.

XI. e - NO PRODUCT PROBES:

Occurs when either a BY TEMP or BY PRODUCT chill cycle has been at- tempted, but no food probes are connected. Unit automatically switches to IDLE mode.

XI. f - OVER TEMPERATURE:

Occurs when cabinet air temperature rises above 160°F. Unit automati- cally turns off all compressors, fans and defrost heaters. NOTE: To reset control after an OVER TEMPERATURE alarm it is necessary to either turn OFF or unplug the unit.

XI. g - PRODUCT DETECTED W/O CYCLE STARTED:

Occurs when cabinet air temperature rises above 40F for ten minutes (with product in the unit but no chill cycle started). Unit automatically switches to a refrigerated holding cycle.

XI. h - CABINET AIR TEMPERATURE SENSOR:

Occurs when the cabinet air sensor has shorted or is open. Unit automati- cally turns off compressors, fans and defrost heaters.

NOTE: To reset the control after an air temperature sensor failure, it is necessary to turn off or unplug the unit and replace the faulty air tempera- ture sensor.