VII. OPERATING THE BLAST CHILL CONTROL - SYSPAR

VII. j - SYSPAR - SETTING THE VARIOUS CONTROL FEATURES:

By accessing SYSPAR (system parameters), the operator can adjust many control features to better suit their operational needs, such as: Clock Settings, Probes, Temperature Scale (F or C), Alarm Settings and Chill Parameters. It also provides for an easy return to the original factory default settings with a RESET feature.

From the SETUP screen, select SYS PAR to get:

Press to select SYS PAR.

SYS PAR: SET CLOCK

Press to select SYS PAR.

Press to decrease ITEM.

Press to increase ITEM.

ITEM:MONTH

 

Press to decrease VALUE.

VALUE:APRIL

 

Press to increase VALUE.

Press to return to MAIN MENU*

CANCEL

ENTER

Press to return to SETUP with saving.

 

 

*without saving.

SYS PAR Menu Display

1)SET CLOCK

a)MONTH (JANUARY – DECEMBER)

b)DATE (1 – 311 )

c)YEAR (2003 – 2079)

d)DAY OF WEEK (SUNDAY – SATURDAY)

e)HOUR (0 – 23)

f)MINUTE (0 – 59)

g)DLS TIME (ENABLED – DISABLED)

2)PROBES

a)

1 (ON – OFF) b)

2 (ON – OFF)

c)3 (ON – OFF)

3) DISPLAY

a)TEMPERATURES (IN DEG C – IN DEG F)

4) LOGGING

a)TIME (5-MINUTES30-MINUTES)

5) ALARM

a)CYCLE RUNNING (NO – yes)

b)CYCLE ENDS (NO – yes)

c)PRINTER ERROR (NO – yes)

d)HIGH/LOW TEMP (no – YES)

e)POWER FAILURE (no – YES)

6)REMINDERS

a)DOOR OPEN (0 – 2 MINUTES)

7)BLAST

a)

TARGET (33 – 40)

b)

AIR (10 – 40)

c)

HOLD (10 – 40)

d)

HIGH ALARM (35 – 60)

e)LOW ALARM (-30 – 34)

8)SOFT CHILL

a)

BY TEMP (5 – 20)

b)

BY TIME (10 – 90)

c)2ND TEMP (10 – 40)

9)FREEZE CHILL

a)

TARGET (-22 – 28)

b)

AIR (-32 – 20)

c)

HOLD (10 – 40)

d)

HIGH ALARM (20 – 45)

e)LOW ALARM (-30 – 0)

10) RESET

a)PARAMETERS (YES – NO)

SYS PAR:

SET CLOCK

ITEM:MONTH

VALUE:APRIL

CANCEL

ENTER

SYS PAR:

SET CLOCK

ITEM:DATE

 

VALUE:04/XX/00

CANCEL

ENTER

SYS PAR:

SET CLOCK

ITEM:YEAR

 

VALUE:04/14/XX

CANCEL

ENTER

SYS PAR:

SET CLOCK

ITEM:HOUR

 

VALUE:XX:00

CANCEL

ENTER

SYS PAR:

SET CLOCK

ITEM:MINUTE

VALUE:10:XX

CANCEL

ENTER

1Last day is corrected for month and leap year.

-21-

Page 22
Image 22
Traulsen RBC400RT, RBC200RT owner manual Itemmonth, Cancel Enter SYS PAR SET Clock Itemyear