2)Automatic Backup Inflation (MD3087)

Inflation will occur automatically within 10 seconds after the inflator is immersed in water. The water-sensing bobbin will disintegrate,

triggering a spring-loaded plunger, which punctures the CO2 cylinder (Figs. 8 and 10) to inflate the Inflatable PFD.

Information

When inflated, the carbon dioxide (CO2 gas) used to inflate the PFD will slowly escape through the fabric over time. A slight reduction of pressure will be observed after several hours of inflation. Topping up by oral inflation may be required in the event of very prolonged immersion.

IMPORTANT: See Special Considerations for Automatic Devices

3)Oral Inflation

Properly armed and inspected Inflatable PFDs will inflate when manually or automatically activated. However, you can fully inflate the Inflatable PFD by mouth (Fig. 4) should inflation not occur, or if you are in a non-emergency situation. To orally inflate the Inflatable PFD, first locate the oral inflation tube by opening the wearer ’s left front panel of the Inflatable PFD. Remove the dust cap from the end of the oral tube and blow into the tube until the Inflatable PFD is fully inflated.

Place the oral inflator dust cap back in the stowed position (Fig. 6).

WARNING: Avoid double inflation (CO2 cylinder inflation after full oral inflation) as it could damage the PFD.

FIGURE 4

Inflatable PFD Owner’s Manual

6

Image 8
Contents MD3085 Inflatable PFD Contents Approval Conditions and Carriage Requirements What is AN Inflatable PFD? Instructions for USEUninspected Commercial Vessel Use Component Inspection InstructionsSizing and Fit Readiness ChecklistDonning Instructions Inflating Your Inflatable PFD Manual InflationOral Inflation Automatic Backup Inflation MD3087Information Special Considerations for Automatic Devices MD3087 Deflating the Inflatable PFDImportant Follow instructions in the exact sequence below Usage Below FreezingRe-arming Your PFD MD3085 MD3085 Manual Inflator Re-arming Your PFD MD3087 MD3087 Automatic Inflator Removed prior to re-armingTop Repacking Is Your PFD in Good and Serviceable CONDITION? Care and Maintenance InstructionsBefore Each Use Every Two 2 MonthsCleaning and Storing of Your Inflatable PFD MD3085 Cleaning and Storing of Your Inflatable PFD MD3087 HOW and WHY to Test Your PFDModel MD3087 Put on the Inflatable PFDHOW do YOU Test Your PFD Using the Oral INFLATOR? HOW do YOU Test Your PFD Using the Manual INFLATOR?Wear Your PFD HypothermiaHow hypothermia affects most adults OverInflatable PFD Safety Accessories Additional Information Do not Attach PFD’S to Your BoatWE Save Lives for a Living