S1000 Autopilot Installation Guide | 31 |
Specifications
System
Approved by: FCC (USA), CE (Europe), IC (Canada)
Autopilot pump
Current consumption: 4 A at 100 psi (69 kP), 7 A at 500 psi (3449 kP)
Dimensions: 6.5 in (165 mm) x 2.5 in (65 mm) x 3.2 in (82 mm)
Weight: 3 lbs (1.4 kg)
Course computer
Voltage: 10 V dc to 16 V dc
Current consumption: 4 A nominal, with autopilot pump running
Dimensions: 6.5 in (165 mm) x 6.7 in (170 mm) x 1.73 in (44 mm)
Data In/Out: SeaTalk, NMEA 0183
S100 Remote
Voltage: 3 V, supplied by two internal, ‘AAA’ batteries.
Dimensions: S100 Remote only: 101 mm x 60.5 mm x 35 mm
Remote in cradle:103 mm x 66 mm x 44 mm
Waterproofing: IPX 6 and IPX 7
Hydraulic fittings
Tapered thread: ¼ NPT (National Pipe Thread)
Hose connection thread: 9/16 UNEF (Unified Extra Fine)
Hydraulic fluid
Recommended Type: SeaStar/BayStar Marine Steering Fluid
Other suitable Types: Texaco HO15
Shell Aero 4
Esso Univis N15
Chevron Aviation Fluid A
Mobil Aero HFA
Fluids meeting MIL H5606 specifications