Furuno FAR-2167DS-BB, FAR-2167DS-D installation manual How to hoist the antenna unit

Page 12

How to hoist the antenna unit

1.Fix the antenna radiator to the antenna unit chassis as shown on page 1-3.

2.Attach the lifting fixtures and collars as shown below.

3.Position the radiator as shown below and arrange the ropes A and B.

Lifting fixture

Supplied as accessories.

 

 

Collar

Remove after installation.

 

Spring washer

 

 

Spring washer

 

 

 

 

 

 

Hex bolt (M12x20)

Flat washer (M12) (Torque: 63.5 Nm)

Lifting hook (2 pcs.)

Remove lifting fixture, coat threads of hex bolts with silicone grease, and then insert bolts in antenna chassis.

 

*

B 1.8m

A 2m

 

 

 

*

* 2. Place protective material (cardboard, foam, etc.) between rope and radiator at the asterisk-marked locations, to prevent damage to radiator.

Attachment of lifting fixtures, collar and ropes

1-4

Image 12
Contents Installation manual 00014869014 Safety Instructions Use only the specified power cables System Configuration IiiStandard supply Name Type Code No Qty RemarksOptional equipment Name Type Code No RemarksThis page is intentionally left blank Antenna Unit Mounting considerations Siting MountingInstallation precaution for S-band antenna unit Mounting precaution for S-band antenna unitAssembling the antenna unit Assembling the antenna unitHow to hoist the antenna unit Attachment of lifting fixtures, collar and ropesInstallation of reinforcement ribs Fastening the antenna unit to the mounting platformMounting the antenna unit Mounting procedure Monitor UnitFlush mounting Contents of desktop mounting kit FP03-09820 Desktop mountingAttaching hand grips Control Unit Fixing with KB keyboard fixing plateMounting dimensions for control unit RCU-014 Mounting dimensions for control unit RCU-015/RCU-016Fixing without KB fixing plate Contents of flush mount kit for RCU-014/015/016 Name Type QtyConnecting RCU-016 in series with RCU-014 Control unit RCU-014, inside viewChanging the cable entrance on control unit RCU-015/RCU-016 Changing cable entrance on control unit RCU-015/RCU-016Mounting dimensions for processor unit Processor UnitPower Supply Unit Mounting dimensions for power supply unitWiring Wiring OverviewFabricating signal cable RW-9600 and HV cable TYPCY-1.5 Fabricating signal cable RW-9600Antenna unit, front view Armor Gasket Signal cable Flat washer Flat washer Gland nut How to wire Wago connector How to fabricate HV cable TYPCY-1.5Fabricating the power cable TYPCY-2.5 How to fabricate power cable TYPCY-2.5Passing flat washer, etc. onto HV cable Antenna unit, left-side viewFabricating the power cable DPYC-2.5 Fabricating power cable DPYC-2.5Monitor Unit for FAR-2167DS Monitor unit MU-201CR, rear viewProcessor Unit Connection of cables Processor unit, rear viewCable XH10P-W-6P L=20/30M Location of connectors Location of connectors inside the processor unitSignal cable RW-9600 Between antenna unit and processor unit Power cable TPYC-1.5Connection of Sub-display Port Conventional remote display FAR-2167DSPower supply unit, inside view Fabricating cable connected to terminal TB1, TB2, TB3Terminal TB1 cable DPYC-2.5 Armor Changing AC Power Specification Power supply Fuse Jumper connector P108Processor unit Processor unit, inside viewHow to adjust the overvoltage detection circuit Power supply unit Power Fuse Jumper connector P8How to adjust the overvoltage detection circuit Adjustments Initializing TuningHeading Alignment Heading alignmentFor Control Unit RCU-014 For Control Unit RCU-015Initialize menu Echo ADJ menuHow to access the Initialize Menu with Control Unit RCU-015 Adjusting Sweep Timing Examples of correct and incorrect sweep timingsSuppressing Main Bang Other Settings Echo menu settingScanner menu Blind Sector 1 and Blind SectorANT SW and ANT Stopped Installation menu Radar no and Radar PosnOn Time and TX Time OWN Ship Info menu LENGTH/WIDTH, Scanner Posn and SUB Scanner PosnGPS 1 ANT Posn and GPS 2 ANT Posn Arpa Preset menu ARP W/O Gyro Not shown on IMO radarARP-related menus ANT Select Other menu EAV w/o GyroOther menu This page intentionally left blank Installing the Gyro Converter board Gyro Converter GC-10Fixing Gyro Converter board inside the processor unit Connecting connector assemblies inside processor unit Wiring Wago connectorAttaching plastic cover for Gyro Converter board Connection of external power supply DIP switch, jumper wire settingsDefault setting Connection of external power supply to Gyro Converter boardJP1 Setting method 2 by make and model of gyrocompass JP1 JP2 JP3 JP4 JP564P1106 Gyro Converter boardSetting the heading readout on the radar display HDG menuFlush mounting dimensions for memory card interface unit Memory Card Interface UnitConnections Desktop mountOne memory card if unit and one processor unit One memory card if unit and multiple processor unitsType Code No Contents How to wire the DVI-RBG conversion board DVI-RGB Conversion KitProcessor unit, side view Processor unit bottom chassisConnecting wires to the housing BNC Connector Converter DVI-RGBData Specifications Contents Remarks InputOutput IEC 61162 input sentence and priority IEC 61162 output sentenceSentence and order of priority SentencePacking List 1 SN30AF/SN36AF 70+6 000-157-497-10 工事材料表 000-155-826-10 PSU-006 AC100V 付属品表 03GL-X-9506 . CU-200-FAR GC-10-2 GC-10 $40# Page Page May 1707 R.Esumi Sep/2010 Y.NISHIYAMA Page Jan.1808 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Page Page Page Page Page Page Page Page Page Interconnection Diagram