Furuno FAR-2167DS-D Connecting connector assemblies inside processor unit, Wiring Wago connector

Page 59

5.Connect J602 (attached at step 3) to the GYRO CONVERTER board with two VH connector assemblies 03-2089 (3P) and 03-2090 (5P).

2

Connection for J602

Wiring WAGO connector

Press downward.

Terminal opener

J602

1

Connection for P608

 

PPL

 

 

 

From J4

 

7

 

BLU

 

 

 

 

 

 

6

 

 

GRN

 

 

 

5

 

 

YEL

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

ORG

 

 

 

 

 

3

 

 

RED

 

 

 

 

 

 

From J5

 

2

 

 

BRN

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

2VH connector assy. 03-2089 (5P)

WAGO connector

Twist Wire

Procedure

1.Twist core.

2.Press terminal opener downward.

3.Insert wire to hole.

4.Remove terminal opener.

5.Pull wire to confirm that it is secure.

P608

 

 

 

4

 

 

YEL

 

 

 

 

 

 

ORG

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

RED

 

 

 

2

 

 

 

 

 

 

 

BRN

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1NH connector assy. 03-2091 (5P)

2VH connector assy. 03-2090 (3P)

P5

To J602

 

XH-PH connector assy.

To P608

 

03-2088 (6-14P)

P4

P7

P1

 

 

 

P603

 

2 1

J5

4

 

 

1

P608

1

 

3

 

3

 

1

1

 

 

5

 

1

 

2

 

1

J4

J603

GYRO CONVERTER 64P1106A

J7

7

J602

 

1

2

1

TB 03P9342

J1

1

1

Connecting connector assemblies inside processor unit

6.Confirm gyrocompass specifications and set up the DIP switches and jumper wires on the GYRO CONVERTER board according to gyrocompass connected:

Setting jumper wires and DIP switches by gyrocompass specifications: page 4-6

Setting jumper wires and DIP switches by make and model of gyrocompass: page 4-7

Location of jumper wires and DIP switches: page 4-8

4-3

Image 59
Contents Installation manual 00014869014 Safety Instructions Use only the specified power cables Iii System ConfigurationName Type Code No Qty Remarks Standard supplyName Type Code No Remarks Optional equipmentThis page is intentionally left blank Mounting Antenna UnitMounting considerations SitingMounting precaution for S-band antenna unit Installation precaution for S-band antenna unitAssembling the antenna unit Assembling the antenna unitAttachment of lifting fixtures, collar and ropes How to hoist the antenna unitFastening the antenna unit to the mounting platform Installation of reinforcement ribsMounting the antenna unit Flush mounting Mounting procedureMonitor Unit Desktop mounting Contents of desktop mounting kit FP03-09820Attaching hand grips Fixing with KB keyboard fixing plate Control UnitFixing without KB fixing plate Mounting dimensions for control unit RCU-014Mounting dimensions for control unit RCU-015/RCU-016 Name Type Qty Contents of flush mount kit for RCU-014/015/016Control unit RCU-014, inside view Connecting RCU-016 in series with RCU-014Changing cable entrance on control unit RCU-015/RCU-016 Changing the cable entrance on control unit RCU-015/RCU-016Processor Unit Mounting dimensions for processor unitMounting dimensions for power supply unit Power Supply UnitWiring Overview WiringAntenna unit, front view Fabricating signal cable RW-9600 and HV cable TYPCY-1.5Fabricating signal cable RW-9600 Armor Gasket Signal cable Flat washer Flat washer Gland nut How to fabricate HV cable TYPCY-1.5 How to wire Wago connectorHow to fabricate power cable TYPCY-2.5 Fabricating the power cable TYPCY-2.5Antenna unit, left-side view Passing flat washer, etc. onto HV cableMonitor unit MU-201CR, rear view Fabricating the power cable DPYC-2.5Fabricating power cable DPYC-2.5 Monitor Unit for FAR-2167DSProcessor Unit Cable XH10P-W-6P L=20/30M Connection of cablesProcessor unit, rear view Location of connectors inside the processor unit Location of connectorsPower cable TPYC-1.5 Signal cable RW-9600 Between antenna unit and processor unitPort Conventional remote display FAR-2167DS Connection of Sub-displayTerminal TB1 cable DPYC-2.5 Power supply unit, inside viewFabricating cable connected to terminal TB1, TB2, TB3 Armor Processor unit, inside view Changing AC Power SpecificationPower supply Fuse Jumper connector P108 Processor unitHow to adjust the overvoltage detection circuit Power Fuse Jumper connector P8 Power supply unitHow to adjust the overvoltage detection circuit Initializing Tuning AdjustmentsHeading alignment Heading AlignmentEcho ADJ menu For Control Unit RCU-014For Control Unit RCU-015 Initialize menuHow to access the Initialize Menu with Control Unit RCU-015 Examples of correct and incorrect sweep timings Adjusting Sweep TimingSuppressing Main Bang Echo menu setting Other SettingsANT SW and ANT Stopped Scanner menuBlind Sector 1 and Blind Sector On Time and TX Time Installation menuRadar no and Radar Posn GPS 1 ANT Posn and GPS 2 ANT Posn OWN Ship Info menuLENGTH/WIDTH, Scanner Posn and SUB Scanner Posn ARP-related menus Arpa Preset menuARP W/O Gyro Not shown on IMO radar ANT Select Other menu Other menuEAV w/o Gyro This page intentionally left blank Gyro Converter GC-10 Installing the Gyro Converter boardFixing Gyro Converter board inside the processor unit Wiring Wago connector Connecting connector assemblies inside processor unitAttaching plastic cover for Gyro Converter board Connection of external power supply to Gyro Converter board Connection of external power supplyDIP switch, jumper wire settings Default settingJP1 JP1 JP2 JP3 JP4 JP5 Setting method 2 by make and model of gyrocompassGyro Converter board 64P1106HDG menu Setting the heading readout on the radar displayMemory Card Interface Unit Flush mounting dimensions for memory card interface unitOne memory card if unit and multiple processor units ConnectionsDesktop mount One memory card if unit and one processor unitType Code No Contents DVI-RGB Conversion Kit How to wire the DVI-RBG conversion boardProcessor unit bottom chassis Processor unit, side viewConnecting wires to the housing DVI-RGB BNC Connector ConverterOutput Data Specifications Contents RemarksInput Sentence IEC 61162 input sentence and priorityIEC 61162 output sentence Sentence and order of priorityPacking List 1 SN30AF/SN36AF 70+6 000-157-497-10 工事材料表 000-155-826-10 PSU-006 AC100V 付属品表 03GL-X-9506 . CU-200-FAR GC-10-2 GC-10 $40# Page Page May 1707 R.Esumi Sep/2010 Y.NISHIYAMA Page Jan.1808 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Apr.2307 R.Esumi Page Page Page Page Page Page Page Page Page Interconnection Diagram