Installation
Close to | Long DC cables must be very large (and expensive), so |
battery | they should be kept short (see Table |
compartment | However, the unit should NOT be installed in the battery |
| compartment due to the possible presence of explosive |
| hydrogen gas from the batteries. |
Protected | Never allow battery acid to drip on the inverter or its |
from battery | wiring when filling the batteries or reading their specific |
acid and | gravity. Do not mount the unit where it will be exposed to |
gases | gases produced by the batteries. These gases are corrosive |
| and prolonged exposure will damage the inverter. |
Orientation | To meet regulatory requirements, the TS400 must be |
| mounted on a flat horizontal surface with the front panel in |
| the upright position. |
Battery Requirements
CAUTION
The TS400 Sine Wave Inverter must only be connected to batteries with a nominal output voltage of 12 volts. The TS400 Sine Wave Inverter will not operate from a 6 volt battery and will be damaged if connected to a 24 volt battery.
The batteries that you use strongly affect the performance of the TS400. It is important to connect the inverter to the correct size and type of battery.
See Appendix B, “Battery Types and Sizes” on page