Installation

Step 4: Installing the Optional S400 Remote Switch

WARNING: Shock hazard

Before making an opening in a wall, bulkhead or panel, ensure there is no wiring or other obstruction within the wall.

WARNING: Shock hazard

Ensure both the S400 Remote Switch and the TS400 are in

Standby ( ) mode before installing.

Installing the S400 Remote Switch (Xantrex product number 808-2400) is optional. The TS400 operates normally without the remote switch.

The S400 Remote Switch is designed to be flush mounted on a wall, bulkhead or panel. A 25 foot (7.5 meter) telephone cable is supplied with the remote switch.

If you want to extend the cable, use a high quality, 4-wire telephone extension cable with 6-position, 4-contact connectors. The maximum recommended cable length is 50 feet (15 meters).

For your convenience, a full-scale mounting template is provided on page 2–24.

Note: The S400 Remote Switch connects to a jack at the back of the inverter. See “System Diagram” on page 2–2.

To install the remote switch:

1.Choose a location that is dry, free from corrosive or explosive fumes, and otherwise appropriate for installing an electronic device.

2.Using the template, pilot-drill the mounting holes. Cut an opening about 2 inches x 1.2 inches (50 mm x 30 mm) and 1.4 inches (35 mm) deep.

3.Route the telephone cable inside the wall and through the opening to the inverter.

2–12

975-0055-01-01

Image 34
Contents TS400 Sine Wave Inverter Page TS400 Sine Wave Inverter DWHDQG5HYLVLRQ Audience PurposeScope OrganizationConventions Used Acronyms and Terminology Related InformationPage Important Safety Instructions General PrecautionsPrecautions When Working With Batteries Explosive Gas PrecautionsFCC Information to the User Page Contents Battery Types and Sizes TroubleshootingSpecifications Operation975-0055-01-01 Xiii Xiv Introduction Premium Power and Ease of Use How TS400 WorksComprehensive Protection 7KLVSURWHFWLRQIHDWXUH«Front Panel TS400 FeaturesHdwxuh Hvfulswlrq Back Panel HvfulswlrqDimensions of Remote Switch Optional Accessory Remote SwitchPart number of Remote Switch Installation Introduction InverterPreparing for Installation Installation CodesInstallation Tools and Materials Materials ListMaterials for AC output hardwiring Designing Your Installation Installing the TS400Overview Choosing a Location Battery Requirements DC Cables HdfkfdeohMounting Your Inverter To mount your TS400Connecting the Chassis Ground To connect the chassis groundInstalling the Optional S400 Remote Switch To install the remote switch3Connecting Cable to the TS400 Getting Ready to Connect the DC Cables To prepare the DC cablesRouting the DC Cables Guidelines for Routing the DC CablesConnecting the DC Cables 5Connection Order for DC CablesTo connect the DC cables Connecting Your Equipment to the Gfci Outlets To connect your AC equipment to the Gfci outletsHardwiring the AC Output To hardwire the AC output connections7Removing the 3 Screws on the Wiring Box Access Panel 8Completing the Hardwiring Performing Checks Prior to Initial Start-up Testing Your InstallationTo test the TS400 9Inverter Dimensions 10S400 Remote Switch Mounting Template Scale approximately Operation Front Panel Features Panel of the TS400 on page 1-4 in the Introduction chapterTurning the TS400 On Turning the TS400 to Standby When Not in UseOperating the TS400 To turn the TS400 onUsing the Optional S400 Remote Switch 2S400 Remote SwitchRecharging Your Batteries Recovering from Low Battery Voltage ShutdownTo recover from a low battery voltage shutdown Restarting or Operating Multiple Pieces of EquipmentMonitoring the Operating Status Ljkw Roru 6WDWXV $FWLRQResetting After a Fault or Shutdown Dxow 6WDWXV $FWLRQPage Troubleshooting Troubleshooting Reference Front Panel1Troubleshooting Reference 3UREOHP 3RVVLEOH&DXVH3UREOHP 3RVVLEOH&DXVH 6ROXWLRQ Specifications Electrical Specifications Physical Specifications with ProjectionsRegulatory Approvals Fan Cooling SystemPage Battery Types and Sizes Automotive Starting Batteries Battery TypesDeep-Cycle Batteries Battery Size To determine how much battery capacity you need Estimating Battery RequirementsBattery Sizing Example 7LPHSHUD\ Dssoldqfh $SSOLDQFH Dwwv +RXUVBattery Sizing Worksheet Two Separate Battery Banks Using Multiple BatteriesTwo Batteries Connected In Parallel Battery Tips 6WDWHRI&KDUJH Warranty and Product Information WarrantyProduct DisclaimerExclusions Return Procedure Return Material Authorization PolicyOut of Warranty Service Information About Your System Information About Your SystemIndex IX-2 975-0055-01-01 IX-3 IX-4 Page Xantrex Technology Inc