Xantrex Technology TS400 manual 7Removing the 3 Screws on the Wiring Box Access Panel

Page 42

Installation

3.Locate the wiring box access panel, and remove the three screws to access the wiring box as shown in Figure 2-7.

Figure 2-7Removing the 3 Screws on the Wiring Box Access Panel

4.Remove the wiring box access panel from the unit.

5.Install a 1/2 inch cable clamp.

6.Locate the terminal block.

The three terminals are labelled as follows:

L Line

N Neutral

Ground

7.Strip about 2 inches (50 mm) off the jacket of the AC output cable.

The AC output cable must be either solid or stranded, within the range of No. 14 to No. 18 AWG, and have three conductors.

8.Strip approximately 3/8 inch (10 mm) off the insulation of the cable.

9.Run the AC cable through the cable clamp and into the wiring box.

10.Using the 1/8 inch slot screwdriver, loosen the wire attachment screws on the terminals by five turns.

11.Insert and fasten the Ground wire into the corresponding terminal.

12.Insert the Line and Neutral wires into the corresponding terminals.

2–20

975-0055-01-01

Image 42
Contents TS400 Sine Wave Inverter Page TS400 Sine Wave Inverter DWHDQG5HYLVLRQ Audience PurposeScope OrganizationConventions Used Acronyms and Terminology Related InformationPage Important Safety Instructions General PrecautionsPrecautions When Working With Batteries Explosive Gas PrecautionsFCC Information to the User Page Contents Battery Types and Sizes TroubleshootingSpecifications Operation975-0055-01-01 Xiii Xiv Introduction Premium Power and Ease of Use How TS400 WorksComprehensive Protection 7KLVSURWHFWLRQIHDWXUH«TS400 Features Front PanelHdwxuh Hvfulswlrq Back Panel HvfulswlrqOptional Accessory Remote Switch Dimensions of Remote SwitchPart number of Remote Switch Installation Introduction InverterPreparing for Installation Installation CodesInstallation Tools and Materials Materials ListMaterials for AC output hardwiring Installing the TS400 Designing Your InstallationOverview Choosing a Location Battery Requirements DC Cables HdfkfdeohMounting Your Inverter To mount your TS400Connecting the Chassis Ground To connect the chassis groundInstalling the Optional S400 Remote Switch To install the remote switch3Connecting Cable to the TS400 Getting Ready to Connect the DC Cables To prepare the DC cablesRouting the DC Cables Guidelines for Routing the DC CablesConnecting the DC Cables 5Connection Order for DC CablesTo connect the DC cables Connecting Your Equipment to the Gfci Outlets To connect your AC equipment to the Gfci outletsHardwiring the AC Output To hardwire the AC output connections7Removing the 3 Screws on the Wiring Box Access Panel 8Completing the Hardwiring Testing Your Installation Performing Checks Prior to Initial Start-upTo test the TS400 9Inverter Dimensions 10S400 Remote Switch Mounting Template Scale approximately Operation Front Panel Features Panel of the TS400 on page 1-4 in the Introduction chapterTurning the TS400 On Turning the TS400 to Standby When Not in UseOperating the TS400 To turn the TS400 onUsing the Optional S400 Remote Switch 2S400 Remote SwitchRecharging Your Batteries Recovering from Low Battery Voltage ShutdownTo recover from a low battery voltage shutdown Restarting or Operating Multiple Pieces of EquipmentMonitoring the Operating Status Ljkw Roru 6WDWXV $FWLRQResetting After a Fault or Shutdown Dxow 6WDWXV $FWLRQPage Troubleshooting Troubleshooting Reference Front Panel1Troubleshooting Reference 3UREOHP 3RVVLEOH&DXVH3UREOHP 3RVVLEOH&DXVH 6ROXWLRQ Specifications Electrical Specifications Physical Specifications with ProjectionsRegulatory Approvals Fan Cooling SystemPage Battery Types and Sizes Battery Types Automotive Starting BatteriesDeep-Cycle Batteries Battery Size To determine how much battery capacity you need Estimating Battery RequirementsBattery Sizing Example 7LPHSHUD\ Dssoldqfh $SSOLDQFH Dwwv +RXUVBattery Sizing Worksheet Using Multiple Batteries Two Separate Battery BanksTwo Batteries Connected In Parallel Battery Tips 6WDWHRI&KDUJH Warranty and Product Information WarrantyDisclaimer ProductExclusions Return Material Authorization Policy Return ProcedureOut of Warranty Service Information About Your System Information About Your SystemIndex IX-2 975-0055-01-01 IX-3 IX-4 Page Xantrex Technology Inc