Step 3: Connecting the Chassis Ground

The chassis ground lug is used to connect the chassis of the inverter to your system’s chassis grounding point, as required by installation codes.

Use copper cable that is either bare or provided with green insulation. Do not use the chassis ground lug for your AC output grounding wire.

To connect the chassis ground:

Refer to Figure 2-2.

1.Using the 1/4 inch slot screwdriver, loosen the screw on the chassis ground lug.

2.Connect a No. 8 AWG copper cable between the inverter’s chassis ground lug and the DC grounding point for your system.

In an RV or vehicle installation, this will usually be the vehicle chassis or a dedicated chassis ground bus.

3.Tighten the screw to a torque of 6–7 lbf-in (0.68–0.79 Nm).

Figure 2-2Connecting the Chassis Ground

975-0055-01-01

2–11

Image 33
Contents TS400 Sine Wave Inverter Page TS400 Sine Wave Inverter DWHDQG5HYLVLRQ Scope PurposeAudience OrganizationConventions Used Related Information Acronyms and TerminologyPage General Precautions Important Safety InstructionsExplosive Gas Precautions Precautions When Working With BatteriesFCC Information to the User Page Contents Specifications TroubleshootingBattery Types and Sizes Operation975-0055-01-01 Xiii Xiv Introduction How TS400 Works Premium Power and Ease of Use7KLVSURWHFWLRQIHDWXUH« Comprehensive ProtectionTS400 Features Front PanelHdwxuh Hvfulswlrq Hvfulswlrq Back PanelOptional Accessory Remote Switch Dimensions of Remote SwitchPart number of Remote Switch Installation Inverter IntroductionInstallation Codes Preparing for InstallationMaterials List Installation Tools and MaterialsMaterials for AC output hardwiring Installing the TS400 Designing Your InstallationOverview Choosing a Location Battery Requirements Hdfkfdeoh DC CablesTo mount your TS400 Mounting Your InverterTo connect the chassis ground Connecting the Chassis GroundTo install the remote switch Installing the Optional S400 Remote Switch3Connecting Cable to the TS400 To prepare the DC cables Getting Ready to Connect the DC CablesGuidelines for Routing the DC Cables Routing the DC Cables5Connection Order for DC Cables Connecting the DC CablesTo connect the DC cables To connect your AC equipment to the Gfci outlets Connecting Your Equipment to the Gfci OutletsTo hardwire the AC output connections Hardwiring the AC Output7Removing the 3 Screws on the Wiring Box Access Panel 8Completing the Hardwiring Testing Your Installation Performing Checks Prior to Initial Start-upTo test the TS400 9Inverter Dimensions 10S400 Remote Switch Mounting Template Scale approximately Operation Panel of the TS400 on page 1-4 in the Introduction chapter Front Panel FeaturesOperating the TS400 Turning the TS400 to Standby When Not in UseTurning the TS400 On To turn the TS400 on2S400 Remote Switch Using the Optional S400 Remote SwitchTo recover from a low battery voltage shutdown Recovering from Low Battery Voltage ShutdownRecharging Your Batteries Restarting or Operating Multiple Pieces of EquipmentLjkw Roru 6WDWXV $FWLRQ Monitoring the Operating StatusDxow 6WDWXV $FWLRQ Resetting After a Fault or ShutdownPage Troubleshooting Front Panel Troubleshooting Reference3UREOHP 3RVVLEOH&DXVH 1Troubleshooting Reference3UREOHP 3RVVLEOH&DXVH 6ROXWLRQ Specifications Physical Specifications with Projections Electrical SpecificationsFan Cooling System Regulatory ApprovalsPage Battery Types and Sizes Battery Types Automotive Starting BatteriesDeep-Cycle Batteries Battery Size Battery Sizing Example Estimating Battery RequirementsTo determine how much battery capacity you need 7LPHSHUD\ Dssoldqfh $SSOLDQFH Dwwv +RXUVBattery Sizing Worksheet Using Multiple Batteries Two Separate Battery BanksTwo Batteries Connected In Parallel Battery Tips 6WDWHRI&KDUJH Warranty Warranty and Product InformationDisclaimer ProductExclusions Return Material Authorization Policy Return ProcedureOut of Warranty Service Information About Your System Information About Your SystemIndex IX-2 975-0055-01-01 IX-3 IX-4 Page Xantrex Technology Inc