Index Interfurn 90-823226 manual Filling System with Fluid, Maintenance

Page 19

Filling System with Fluid

1.Fill pump reservoirs with automatic transmission fluid (ATF) Dexron ll or Dexron lll.

2.Install and tighten pump cap by turning cap clock- wise approximately 120 degrees.

a

72868

a - Cap

3.Fill reservoir bottle to full mark, then (one at a time) slightly loosen pump cap to allow fluid to flow from reservoir to pump until pump just starts to overflow, then quickly tighten pump cap. Fill bottle reservoir and repeat this process for the other pump.

4.Double check both caps to ensure they are both tight.

Index

Maintenance

Maintenance inspection is the owner's responsibility and must be performed at the following intervals:

Normal Service - Every 50 hrs. of operation or 60 days (whichever comes first)

Severe Service - Every 25 hrs. of operation or 30 days (whichever comes first)

NOTE: Operation in salt water is considered se- vere service.

1.Check all connections and hose clamps for ade- quate tightness. Tighten, if loose.

2.Check all mounting bolts and tighten if necessary.

3.Be sure to check reservoir oil level periodically.

90-823226--1 996

POWER STEERING - 8A-17

Image 19 Contents
Power Steering Table of Contents Precautions Torque SpecificationsTools/Sealants Power Steering Pump and Components Exploded View Serpentine Belt Routing Pump Pulley Replacement Important Service InformationFilling and Air Bleeding System Testing and Repair Checking Pump Fluid LevelBelt Adjustment Serpentine Belt AdjustmentPump Assembly Earlier Style Control Valve Torque small fitting to Mounting BracketHydraulic Hoses and Fluid Cooler High Pressure Hose Pump-to-Control ValvePort Side Mounted Fluid Cooler Low Pressure Hose Cooler-to-PumpRear Mounted Fluid Cooler Loosen hose clamp and remove hose from back of pump Later Style Control Valve Low Pressure Hose Control Valve-to-CoolerPort Side Mounted Fluid Cooler Only Earlier Style Control ValveEarlier Style Control Valve Torque large fitting to Priority Valve Kit 79691A1 Information Installing ReservoirReservoir Cap Vent Installing Priority Valve Install return hose large fitting on one end only Secure all hoses with Sta-Straps provided Filling System with Fluid MaintenancePressure Line Return Line Gravity Feed Line System Flow DiagramPower Steering 8A-19