9.Run pump until cleaning ball exits material hose. Save cleaning ball (Base Coat Only).
Cleanup
14.Add additional water and repeat steps 12 - 13 if nec- essary.
ti4551c
10.Turn on/off switch OFF and turn prime/drain valve to DRAIN. Clean outside of pump and suction tube with brush and water.
ti13839a
15.Open prime/drain valve and turn prime switch ON to flush valve.
ti10796b | ti14632a |
11.Connect applicator to material hose. Close prime/drain valve.
ti21038a
12.Turn on/off switch ON.
Base Coat Pump: Turn prime switch ON, or appli- cator switch on material hose.
ti14632a
16.Turn on/off switch OFF when valve is thoroughly flushed.
ti10796b
17.Open over pressure relief valve and turn prime switch ON to flush valve.
ti10795b
13. Run pump until clean water flows from applicator.
ti13633a
ti13641ati21039a
313888E | 19 |