Digital Tracking System (DTS)
Digital Tracking System (DTS)
Main Menu | 4. Short press DTS button to move to Engine RPM. |
Close cover when spraying to protect display.
ti5802a
1.Perform Startup steps 1 - 2.
•Open drain valve
•Turn pump control counterclockwise to lowest set- ting
•Set applicator switch to OFF
2.Start Engine, page 12. Display will momentarily show which pump is installed (Base or Top) and then Flow 1, 2, or 3 (if Base Coat pump is installed). Pressure display appears, then dashes appear when pressure is less than 60 psi (4 bar, 0.4 MPa).
ti5804a
NOTE: Information other than pressure cannot be accessed if applicator switch is ON. And, if system pres- sure is greater than 200 psi (14 bar, 1.4 MPa), the dis- play will revert back to pressure after 3 seconds.
ti13761a
5. Short press DTS button to return to Pressure.
ti13762a
To Change Pressure Units:
Press and hold (8 seconds) DTS button to change pres- sure unit (psi, bar, MPa).
Continue to press DTS button to cycle from psi to bar to MPa. Release DTS button to select units.
psi
bar | ti6225a |
psi | |
MPa |
|
|
|
3. Short press DTS button to display installed pump.
ti13760a