GE Motor Protection System, LM10 instruction manual 4 Changes to Manual Since Release A3

Page 72

REVISION HISTORYCHAPTER 6: MISCELLANEOUS

 

Table 6–3: Changes to Manual Since Release A4

 

 

Section Number

Revision

 

 

3.2.4

Move section to 5.1.10

 

 

5.1.2

Add Poll Data 4

 

 

5.1.6

Add Assembly Object, Class Code 4, Instance 105 (Poll Data Group 4)

 

 

5.1.8

Control Supervisor Object - Delete Section

 

 

5.1.11

Change format code F15 to include Poll Data Group 4

 

 

5.1.11

Add bit locations to format codes F21 and F22

 

 

 

Table 6–4: Changes to Manual Since Release A3

 

 

Section Number

Revision

 

 

 

Update Manual to A4 and Firmware (and Firmware references) to

 

v1.60

 

 

1.3.3

Change revision in the images of the product from 1.50 to 1.60

 

 

1.4.1

Table 1-1 - LM10 Order Code text changed

 

 

1.5.1

Change Ground Fault, Jam, Stall, Current Unbalance, Load Loss

specifications

 

 

 

3.2.3

Change text "The unit has three passcode levels..."

 

 

4.2.1

Changes to Ground Fault Level, Stall Level, Load Loss Level,

Undervoltage, Overvoltage

 

 

 

4.2.6

Changes to Ground Setup, Stall Setup

 

 

4.2.6

Change to equation 4-3

 

 

5.1.6

Assembly Object, Class Code 4, Instance 100

"Security to Min" in Control Byte clarified. Note added.

 

 

 

5.1.6

Change to Assembly Object, Class Code 4, Instance 101, Attribute

3,Bit 6

 

 

 

5.1.11

Change to format code F20

 

 

5.1.11

Change to format code F24

 

 

5.1.2

Change to Identity Object, Class Code 1, Instance 1, Attributes

 

 

5.1.11

Add attribute (Attribute: 0x34)

 

 

5.1.11

New format code: F25 - Input Switch Status

 

 

5.1.11

Add attribute (Attribute: 0x38)

 

 

5.1.11

New format code: F26 - Remaining Cool-Down Period

 

 

5.1.6

Change to Assembly Object, Class Code 4, Instance 52

 

 

5.1.11

Change text description for attribute 0x26

 

 

5.1.11

Correction to F14 format

 

 

5.1.7

Changes to Connection Object, Class Code 5, Instance 2 (polled...)

 

 

5.1.11

Change the ranges for the delays to match range shown in Chapter 4

 

 

5.1.5

Add three additional tables before the "Connection Object" section

 

 

 

Assembly Object, Class Code 4, Instance 100

5.1.6

Change bit 5 from "Reserved" to "Security to Min"

 

Add note at the bottom of the table

 

 

5.1.11

Extension Object, Class Code 0x64, Instance 1

Add a note to "Reset LM10" at attribute 0x2E

 

 

 

5.1.1 - 5.1.5

Miscellaneous text/table changes

 

 

6–66

LM10 MOTOR PROTECTION SYSTEM – INSTRUCTION MANUAL

Image 72
Contents LM10 Motor Protection System Instruction Manual GE Consumer & IndustrialMultilin 1601-0165-A62008 GE Multilin Incorporated. All rights reserved Table of Contents 2 INSTALLATION1 INTRODUCTION 3 INTERFACE4 FUNCTIONALITY 5 COMMUNICATIONS6 MISCELLANEOUS APPENDIXINDEX A-171-IV LM10 Motor Protection System Chapter 1 Introduction 1.1 Description1.1.1 The LM10 Relay 1.2.1 Features 1.2 Overview1.2.2 Current and Voltage Inputs 1.2.3 Relay Outputs1.2.4 Power Supply 1.2.5 Block DiagramFIGURE 1-1 Functional Block Diagram 1.3 Features 1.3.2 LED Indicators1.3.3 Switches 1.3.1 Programming and Display UnitChanges to switch settings will not take effect until power is cycled DIP Switch PositionFIGURE 1-2 LM10 Features Baud Rate1.4 Ordering 1.4.1 Order CodesTable 1-1 LM10 Order Codes LM10Specifications GROUND FAULTPHASE CURRENT 1.5.1 Protection ElementsPOWER POWER FACTORPOWER SUPPLY 1.5.3 Control FunctionsCONTACT INPUT Stop, Reset, DeviceNet control0 to 120 200 to1.5.5 CT Dimensions Ground fault CTThermal overload CT 1.5.6 OutputsEnvironmental Approvals/CertificationSERIAL COMMUNICATIONS 1.5.81-12 LM10 Motor Protection System Chapter 2 Installation 2.1 Wiring2.1.1 DeviceNet 2.1.2 RS232 Port2.1.3 Control Terminals Table 2-1 Control Connections2.1.5 Wiring Diagram 2.1.4 Sensor Pack InputFIGURE 2-4 LM10 Wiring Diagram CHAPTER 2 INSTALLATION2.2 Mounting 2.2.1 LM10 Mounting2.2.2 PDU Door Mount FIGURE 2-6 LM10 Backplate DimensionsFIGURE 2-7 PDU Door-mount Dimensions LM10 Motor Protection System Chapter 3 Interface 3.1 PDU Operations3.1.1 Liquid Crystal Display 3.1.2 LEDspower factor, kW, average current, and current unbalance. Pressing the History button again advances to the next history record 3.2.3 Configuration Menu 3.2 PDU Screens and Menus3.2.1 Main Startup Screen 3.2.2 History Record and Status ScreensRun 2 to Run 1 delay between forward and reverse or between speeds 3.3 EnerVista LM10 Software 3.3.1 Description3.3.2 Functional Details Table 3-1 EnerVista Hot Keys 4.1 Overcurrent Fault Conditions LM10 Motor Protection System Chapter 4 Functionality4.1.1 Descriptions FIGURE 4-1 Cold Motor Trip Curves FIGURE 4-2 Hot Motor Trip Curves CHAPTER 4 FUNCTIONALITY4.1.2 Trip Curves Example FIGURE 4-3 Trip Curve with Jam and Stall EnabledFIGURE 4-4 Cool Down Times Page 4.2 Configuration Settings 4.2.1 OverviewTable 4-1 LM10 Programmable Parameters 4.2.2 Main Menu CONFIGURATION SETTINGSCHAPTER 4 FUNCTIONALITY4-30 PATH Configuration Ø ENGLISH/SPANISH PATH Configuration ØØ CTs & CPTs4.2.3 Language 4.2.4 CTs and CPTs4.2.6 Run 1 and Run 2 Setup PATH Configuration ØØØ Starter TypePATH Configuration ØØØØ Run 1 Setup 4.2.5 Starter TypeΔ = phase current - average current 4.2.8 Other Settings PATH Configuration ØØØØØ Time DelaysPATH Configuration ØØØØØØ Other Settings 4.2.7 Time DelaysDevNet Fault on Reset Run HrsMaintained off Auto Restart off4.2.9 Auxiliary Relay Faults PATH Configuration ØØØØØØØ Aux Relay Faults4.2.10 Passcode and Login PATH Configuration ØØØØØØØØ Aux Relay Faults4.2.12 Factory Default PATH Configuration ØØØØØØØØØ Run OperationsPATH Configuration ØØØØØØØØØØ Factory Default 4.2.11 Run Operations4.3 Status Values 4.3.1 Main MenuRun, Fault RangeThis value can be reset via the Reset Run Hrs configuration setting 4.4 History Values 4.4.1 Last Trip DataRange Overcurrent, Gr. Fault, Jam, Stall CuUnbalance, LdLoss, DevNet Fault, Dev Stop, Voltage, Aux Sense Range 0.0 to 3200.0 AAUX Sense 1 Fault 4.5 Motor Start/Stop LogicMotor Status Running Motor StopMotor RUN Commands Motor STOP CommandsRUN1 Switch Input RUN1 PDU Command4-44 LM10 Motor Protection System Chapter 5 Communications 5.1 DeviceNet Operations5.1.1 Description 5.1.2 Poll DataTable 5-1 Poll Data Group Table 5-2 Poll Data GroupTable 5-3 Poll Data Group Table 5-4 Poll Data Group5.1.3 Identity object 5.1.4 Message Router5.1.5 DeviceNet Object UINT = 16 bit unsigned integer5.1.6 Assembly Object Baud Rate, value 0 to 2 125, 250, and 500 kbpsDevice outputs see format and mapping below Assembly Object, Class Code 4, Instance Data Formats for Device Inputs see belowCHAPTER 5 COMMUNICATIONS Assembly Object, Class Code 4, Instance 5.1.7 Connection Object Connection Object, Class Code 5, ServicesConnection Object, Class Code 5, Attributes Connection Object, Class Code 5, Instance 2 polled input/output connection 5.1.8 ACK Handler Object 5.1.9 Overload ObjectUSINT = 8-bit unsigned integer UINT = 16-bit unsigned integer 5.1.10 Extension Object UINT = 16-bit unsigned integerAccess F2 Ground Fault F7 Power Transformer5.1.11 Data Formats F1 Full Load Current 16-bit unsigned integerF11 Auxiliary Relay Faults 16-bit bitmask F9 Auxiliary Sense 1 / Run1-Run2 Time DelaysF10 Auxiliary Sense 2 / Run2-Run1 Time Delays F12 Starter TypeF14 Other Settings 16-bit Bitmask F15 Poll Data Group enumeration 16-bit unsigned integerF16 Run1-Run2 and Run2-Run1 Time Delay 16-bit unsigned integer F17 Trip ClassF21 Motor Status 8-bit Bitmask F22 Motor Status 16-bit bitmaskF23 16-bit Unsigned Integer F24 Status Word 16-bit bitmaskF25 Input Switch Status 16-bit value use only lower byte 5.1.12 Special ApplicationSent by scanner CANID, MACID, 0x0E, 0x64, 0x01 5.2 Serial Port 5.2.1 Description5-64 LM10 Motor Protection System Chapter 6 Miscellaneous Revision History6.1.1 Release Dates 6.1.2 Changes to the ManualTable 6-4 Changes to Manual Since Release A3 Change to Assembly Object, Class Code 4, Instance 101, AttributeAdd Assembly Object, Class Code 4, Instance 105 Poll Data Group Changes to Connection Object, Class Code 5, Instance 2 polled6.2 Warranty 6.2.1 GE Multilin WarrantyWARRANTY 6-68CHAPTER 6 MISCELLANEOUS LM10 Motor Protection System Appendix A A.1 DeviceNet OverviewA.1.1 Description A.1.2 Controller Area Network CAN A.1.3 DeviceNet OperationsA.1.6 DeviceNet Features A.1.4 Explicit Messaging and Input/Output I/O MessagingA.1.5 Pre-defined Master/Slave Connection Set A.1.7 Maximum Cable Lengths for DeviceNetA.1.8 DeviceNet Specification Highlights Table A-1 Trunk Cable Length SpecificationTable A-2 Drop Cable Length Specification DescriptionThe Object Model Device ProfilesA.2.3 Network Configuration A.2.4 Configuration ProcedureA.2 LM10 and GE Fanuc 90-30 with DeviceNet A.2.1 OverviewA.2.5 Polling Input/Output Connection Z Select GE LM10 under GE MultilinZ Also, set the Scan Interval and Reconnect Time Page Phase A values are displayed in %I00105 223 ⋅ 0.1 amps A.2.6 COS Change of State Input/Output Connection A.2.7 Cyclic Input/Output ConnectionA.2.8 Explicit Messaging Monitoring DataRung 3 has a Block Move word, 3 blocks Login Configuration Level to the LM10 FIGURE A-1 Ladder Logic for Data MonitoringMaking Setting Changes FIGURE A-2 Ladder Logic for Login ConfigurationLogin User Level to the LM10 FIGURE A-3 Ladder Logic for Setting ChangesFIGURE A-4 Ladder Logic for Login User A.3.2 System Setup A.3.4 Setting Up the DeviceNet NetworkA.3 LM10 and Allen-Bradley SLC500 via DeviceNet A.3.1 DescriptionA.3.5 Changing the Mode of Operation A.3.6 Configuring the Slave Device A.3.7 Control and Monitoring of the LM10 A.3.8 Explicit Messaging with the LM10 Relay Table A-3 Status Codes Provided by ODVA Specification A.3.9 Data Table LayoutTable A-4 Data Table Layout A.3.10 Ladder Logic Table A-5 Data to Get Trip ClassTable A-6 Data for Explicit Message Response, M1 Transferred to N20 Table A-7 Data to Get Motor Run Time Table A-8 Data for Explicit Message Response, M1 Transferred to N20Instance, and Attribute FIGURE A-9 Ladder Logic, Rungs 0000 to A-25FIGURE A-10 Ladder Logic, Rungs 0006 to A-26FIGURE A-11 Ladder Logic, Rungs 0009 to A-27A-28 Index Page LM10 MOTOR PROTECTION SYSTEM - INSTRUCTION MANUAL INDEX LM10 MOTOR PROTECTION SYSTEM - INSTRUCTION MANUAL