Page 18

Atlas & Yukon Second Stage

EAN/Nitrox Cleaning is a four step procedure that includes:

Pre-Cleaning with Ultrasonic Acid Bath

Ultrasonic Aqueous Cleaning Bath

Distilled or Demineralized Water Rinse

Final Inspection (direct light, ultraviolet, and wipe test)

NOTE: Although second stage components are not usually exposed to high pressure oxygen enriched air, Genesis Scuba recommends that the same cleaning and assembly procedures be followed for the complete regulator. This prevents the possibility of cross contamination, and guar- antees the integrity of the complete system.

REQUIRED EQUIPMENT:

Dedicated Ultrasonic Cleaner – To avoid contamination, it is important to use a separate cleaner that is kept dedicated for aqueous cleaning, in addition to one used for acidic cleaning. Preferred fea- tures include a built-in timer and a heater.

Screen Dip Basket – Provided with most ultrasonic cleaners, allows the parts to be fully immersed in each solution, and transferred from one container to the next.

Powderless Latex Gloves – Skin oil is another source of potential contamination that can react with oxygen enriched air. Once the parts have been cleaned, gloves must be worn at all times to prevent them from becoming contaminated during handling.

Dedicated Rinse Tub – To avoid recontamination, it is important to use a separate rinse tub that is kept clean and dedicated for aqueous cleaning, in addition to the rinse tub that is used for acidic cleaning.

Incandescent or Fluorescent Lighting – Required during final inspection to detect more obvious signs of contamination.

Ultraviolet Lighting – Required during final inspection to detect contamination that is not visible beneath normal lighting.

Lint Free Cotton Wipes – Required for cleaning and inspection.

Preparing the Workstation

Enriched air cleaning procedures may be carried out in the same work area that is used for servicing air scuba equipment, provided that it is kept reasonably clean, and airborne pollutants (dust, soot, etc.) are not visibly present on surrounding surfaces. Ventilation ducts and windows should be checked to ensure that airflow will not introduce these contaminants while cleaning and service is in process.

To ensure cleanliness, the work surface should be covered with a clean sheet of butcher paper or plastic sheeting.

The technician must wear clean, non-powdered latex or plastic gloves whenever handling cleaned parts (including upgrade parts kit), in order to prevent contamination with skin oil.

Copyright ©2001 Liberty Group

18

Image 18
Contents Atlas & Yukon Contents Scheduled Service About This ManualFunction & Design IntroductionFacility Requirements Recommended Equipment and Suppliers Atlas/ Yukon Specialty ToolsPreliminary Inspection External InspectionImmersion / Leak Test Disassembly Procedures General GuidelinesSerial Number Location Orifice Removal Cover Ring Removal Exhaust Tee Removal Step Atlas Second Stage Only Atlas Retaining Ring RemovalCleaning Procedures Acidic Cleaning Procedure Degrease & Pre-Scrub Fresh Water Rinse Ultrasonic Acid Bath Neutralizing Bath Final RinseEAN/Nitrox Cleaning Procedure For Equipment Used With Oxygen Enriched Air IntroductionPreparing the Workstation Required EquipmentUltrasonic Aqueous Bath Demineralized or Distilled Water Rinse Final Inspection LOW Pressure Hose Assemblies Final Adjustment & Flow Testing Labeling & PackagingReassembly Procedures Atlas Retaining Ring Installation Atlas Second Stage Only Yukon proceed to StepPop p et Installation Orifice Preliminary Setting Final Testing Procedures Inline Adjustment Tool w/ IP GaugeService & Repair Manual Subjective Breathing Test Flowbench Testing optional External Leak TestTroubleshooting Guide Freeflow or leakageSchematic & Parts List Atlas Second Stage EAN/Nitrox & Compressed AirPage Schematic & Parts List Yukon Second Stage G6621 Orifice G5117 Washer