2Preliminary Inspection

se c t i o n

External Inspection

1.Closely examine the conical filter of the first stage to check for any signs that contaminants have entered the system, including sea water, rust, or aluminum oxide.

NOTE: A green discoloration positively indicates that mois- ture has entered the regulator, and internal corrosion may have occurred. Other types of discoloration may indicate that the regulator has been used with a corroded cylinder. Advise the customer of this, and the possible need to obtain service for their cylinder.

2.Slide back the hose protector(s) to inspect the condition of the LP hose at its fittings and along its length. Check closely for any signs of blistering or abrasion, or corrosion of the fittings.

3.Inspect the condition of the mouthpiece to check for torn bite tabs, holes, or deterioration.

Immersion / Leak Test

1.Check to ensure that the regulator is fully assembled and connected to a first stage, and that there are no open ports or hoses. Connect the first stage to a cylinder that is filled with 3,000 psi, and open the cylinder valve to pressurize the regulator.

2.If leakage cannot be heard, or if the source of leakage detected audibly is not obvious, immerse the second stage in fresh water to check further for any signs of air leakage through the mouthpiece and at the hose fitting.

3.Note the source of any leakage found and refer to Table 2 - Troubleshooting to determine its possible cause.

4.Close the cylinder valve and depress the second stage purge cover to depressurize the regulator.

After completing the Preliminary Inspection, proceed to

Section 3 – Disassembly

7

Copyright ©2001 Liberty Group

Image 7
Contents Atlas & Yukon Contents About This Manual Scheduled ServiceIntroduction Function & DesignFacility Requirements Atlas/ Yukon Specialty Tools Recommended Equipment and SuppliersExternal Inspection Preliminary InspectionImmersion / Leak Test General Guidelines Disassembly ProceduresSerial Number Location Orifice Removal Cover Ring Removal Exhaust Tee Removal Step Atlas Retaining Ring Removal Atlas Second Stage OnlyAcidic Cleaning Procedure Cleaning ProceduresFresh Water Rinse Degrease & Pre-ScrubUltrasonic Acid Bath Final Rinse Neutralizing BathFor Equipment Used With Oxygen Enriched Air Introduction EAN/Nitrox Cleaning ProcedureRequired Equipment Preparing the WorkstationUltrasonic Aqueous Bath Demineralized or Distilled Water Rinse Final Inspection LOW Pressure Hose Assemblies Labeling & Packaging Final Adjustment & Flow TestingReassembly Procedures Atlas Second Stage Only Yukon proceed to Step Atlas Retaining Ring InstallationPop p et Installation Orifice Preliminary Setting Inline Adjustment Tool w/ IP Gauge Final Testing ProceduresService & Repair Manual Subjective Breathing Test External Leak Test Flowbench Testing optionalFreeflow or leakage Troubleshooting GuideEAN/Nitrox & Compressed Air Schematic & Parts List Atlas Second StagePage G6621 Orifice G5117 Washer Schematic & Parts List Yukon Second Stage