Troubleshooting
PROBLEM | CAUSE | SOLUTION |
|
|
|
|
|
|
| FTS failed or is not contacting | Check FTS, page 11. |
| correctly. |
|
|
|
|
| FTS not installed correctly. | FTS should be installed close to end |
Hose does not heat. |
| of hose in same environment as gun. |
|
| Verify FTS installation, page 32. |
|
|
|
| Temperature control alarm. | Check temperature display or diag- |
|
| nostic code, page 32. |
|
|
|
Hoses near Reactor are warm, but | Shorted connection or failed hose | With hose heat on and temperature |
hoses downstream are cold. | heating element. | setpoint above displayed hose zone |
|
| temperature, verify voltage between |
|
| connectors at each section of hose. |
|
| Voltage should drop incrementally for |
|
| each section of hose further from |
|
| Reactor. Use safety precautions |
|
| when hose heat is turned on. |
|
|
|