Graco A-25 important safety instructions Air Motor Pump Assembly, PLUG, Pipe

Page 48

Parts

A-25 Air Motor Pump Assembly, 262573

308

3 313

305

4 306

307

314

325 316

315 3 7

3133

319

305314

2

309 301

Ref

Part

Description

Qty.

301

16G915

PLATE, Mounting, Cylinder

1

302

193031

NUT, retaining

2

303

262647

PUMP, displacement, w/lube; iso

1

304

262648

PUMP, displacement; resin

1

305

15J132

LINK, connecting

2

306

183210

PIN, str, hdls

2

307

183169

SPRING, retaining

2

308

M12LP0

MOTOR, air, NXT, 6 in., cycle

1

 

 

only; see manual 312796

 

309

16G929

ROD, tie

4

310

125266

NUT, lock, nylon, m12

4

311

16G926

BRACKET, pump mounting

1

312

117833

ADAPTER, 3/4-16 JIC x 3/8 NPT

2

313

120553

NUT, center lock, 5/8-18

3

314

111799

SCREW, cap, hex hd

4

315

16G914

ADAPTER, rod

1

316

114110

ELBOW, male, swivel

1

317

15K783

ELBOW, street, 90°

1

318

116746

FITTING, barbed, plated

2

319

16G916

PLATE, yoke, pump

1

322

15H108

LABEL, pinch point

1

324

100139

PLUG, PIPE

2

325

15B565

VALVE, 1/4 npt, park

1

322

310 6

 

312

302 5

 

318

324

 

 

317

 

5

304

312

 

 

 

303 5

1

Apply PTFE tape and sealant to non-swiveling pipe threads.

2

Torque to 88.5-124 in.-lbs (10-14 N•m).

 

3

Torque to 32-38 ft-lbs (43-51 N•m). Torque nut (313) after

 

assembly of item pin (306) and spring (307).

 

4

Install adapters so that pins (306) will be in-line with each other.

5

Lubricate threads of pump cylinders (303, 304) and plate (301)

 

with lubricant prior to assembly into mounting plate. Assemble

 

pump cylinder 1/2 thread above flush to one and one half thread

 

above flush of mounting pate surface.

 

6

Torque to 27-32 ft-lbs (37-43 N•m).

 

7

Use blue thread lock (medium).

 

48

3A1570A

Image 48
Contents Important Safety Instructions Repair-PartsContents Proportioner Models SystemsRelated Manuals Manual DescriptionElectric Shock Hazard Fire and Explosion Hazard Equipment Misuse Hazard Important Two-Component Material Information Changing Materials DataTrak Diagnostic Codes Temperature Control Diagnostic CodesSymbol Code Code Name Diagnosis Cause E01 High fluid temperature Causes of E01 ErrorsSensor Connector Continuity Checks Pins Description Reading ChecksE02 High zone current E03 No zone currentE05 Control board over temperature E06 Communication cable unpluggedE99 Loss of communication Pressure Relief ProcedureShutdown Before Beginning RepairParkFlushing Open CloseTroubleshooting ProblemsPower Pumps and PressuresProblem Cause Solution Problem Cause Solution ElectronicsProblem Cause Solution See E04 Fluid Temperature Sen HeaterSor FTS or thermocouple discon Hose Heat System Problem Cause Solution Follow Pressure Relief Procedure, RepairDisconnect Pump Connect Pump Install Air Motor Remove Air MotorAir Filter Element Installation Recirculation / Over Pressure Relief BlockAir Inlet Filter / Water Separator Auto Drain Air Filter Element RemovalTemperature Control Module Temperature Control Module ConnectionsConnector Description Bottom of Power ModulesReplacing Temperature Control Assembly Modules Test SCR CircuitPrimary Heater Heater ElementLine Voltage KW Dual Zone Heater Thermocouple ThermocoupleOvertemperature Switch Check Hose ConnectorsPins Result Heated HoseFluid Temperature Sensor FTS InstallationTest/Removal Transformer Primary Check Transformer Secondary Check Replace TransformerModel Secondary Voltage Replace Circuit Breaker Module Size ComponentPump Lubrication System Pump Lubrication SystemTemperature Display Refer to Reactor A-25 Wiring Schematic,Fluid Inlet Strainer Screen Detail of Membrane Switches and Temperature Display Board Display ModuleReplace DataTrak Battery or Fuse Replace BatteryReplace Fuse Accessories Recommended Spare PartsParts 7984 100 888Torque pump locking nuts to 66-74 ft-lbs 90-100 Nm Part Description Qty CartNipple Control Panel ScrewTemperature Control Wheel KitRef. Part Description Qty Fluid Manifold Fluid Inlet KitKw Dual Zone Heater, 24J788 RingAir Motor Pump Assembly PLUG, PipeAir Tubing Connections Length Connection Outside Ft m FromColor Diameter Breaker Module Reactor A-25 Wiring Schematic PhasePOD Reactor A-25 Wiring Schematic Simplified Schematic, Heater Controls Technical Data Category DataGraco Standard Warranty Graco Information
Related manuals
Manual 38 pages 32.05 Kb