Troubleshooting
Before performing any troubleshooting procedures: 1. Relieve pressure, page 13.
2. | Turn main power OFF | . |
3. | Allow equipment to cool. |
|
Troubleshooting
Problems
Try the recommended solutions in the order given for each problem, to avoid unnecessary repairs. Also, determine that all circuit breakers, switches, and con- trols are properly set and wiring is correct before assum- ing there is a problem.
Power
PROBLEM | CAUSE | SOLUTION |
|
|
|
Heat zones do not operate | No power | Connect power cord |
|
|
|
|
| Turn Main Disconnect Switch ON |
|
|
|
| Power cord not connected properly | Check connections |
|
|
|
No power when disconnect switch is | Power terminal jumper still at 380V, 3 | Place jumpers in correct position; see |
turned on; using 230V, 1 phase or | phase position, as shipped from fac- | Operation manual and label inside |
230V, 3 phase power | tory | front lower cabinet. |
|
|
|
External main supply power circuit | Power terminal jumper was left in | Place jumpers in correct position; see |
breaker trips and Reactor disconnect | 230V, 1 phase position. When using | Operation manual. Replace main |
switch fails when switch is turned on. | 230V, 3 phase or 380V, 3 phase | power disconnect switch; see page |
| power | 40. |
|
|
|
No temperature display lights at | No power | Connect power cord |
startup |
|
|
| Turn Main Disconnect Switch ON | |
|
| |
|
|
|
| Control power fuses blown | Check and replace fuses on long ter- |
|
| minal strip |
|
|
|
Pumps and Pressures
PROBLEM | CAUSE | SOLUTION |
|
|
|
|
|
|
Pump does not run up and down | Motor control valve closed | Open air motor shutoff valve |
|
|
|
| No air supply | Air supply line not connected |
|
|
|
|
| Open inlet air ball valve |
|
|
|
| Air pressure regulators set at 0 psi | Turn up air pressure regulators |
|
|
|
| Air motor shuttle valve is centered. | Push button on top of air motor shut- |
|
| tle valve. |
|
|
|
Pump runs but no fluid pressure | Fluid inlet ball valves closed | Open fluid inlet ball valves |
|
|
|