Troubleshooting
Problem | Cause |
| Solution |
|
|
|
| ||
| Low voltage. | Ensure input voltage is within specifi- | ||
|
| cations, page 36. |
| |
|
|
| ||
| Poor display connection. | Check cable connections, page 36. | ||
Erratic display; display turns on and |
| Replace damaged cable. |
| |
|
|
|
| |
off. | Display cable damaged or corroded. | Clean connections; replace cable if is | ||
|
| damaged. |
|
|
|
|
|
| |
| Display cable not grounded. | Ground cable, page 37. |
| |
|
|
| ||
| Display extension cable too long. | Must not exceed 100 ft (30.5 m) | ||
|
|
| ||
Hose display reads OA at startup. | FTS disconnected or not installed. | Verify proper installation of FTS (see | ||
|
| Operation manual), or adjust FTS to | ||
|
| desired current setting. |
| |
|
|
| ||
| Poor display connection. | Check cable connections, page 36. | ||
|
| Replace damaged cable. |
| |
|
|
| ||
Display does not respond properly to | Display cable damaged or corroded. | Clean connections; replace cable if is | ||
button pushes. |
| damaged. |
|
|
| Ribbon cable on display circuit board | Connect cable (page 36) or replace. | ||
| disconnected or broken. |
|
|
|
|
|
|
| |
| Broken display button. | Replace, page 36. |
| |
|
|
| ||
No hose heat. | Loose hose electrical connections. | Check connections. Repair as neces- | ||
|
| sary. |
|
|
|
|
| ||
| Circuit breakers tripped. | Reset breakers (CB1 or CB2), page | ||
|
| 34. |
|
|
|
|
|
|
|
| Hose zone not turned on. |
|
|
|
|
| Press | zone | key. |
|
|
| ||
| A and B temperature setpoints too | Check. Increase if necessary. | ||
| low. |
|
|
|
|
|
| ||
| Failed temperature control module. | Open cabinet. Check if board LED is | ||
|
| blinking. If not, check power wiring | ||
|
| connections to ensure module has | ||
|
| power. If board has power and LED is | ||
|
| not blinking, replace module, page | ||
|
| 26. |
|
|
|
|
| ||
Low hose heat. | A and B temperature setpoints too | Increase A and B setpoints. Hose | ||
| low. | designed to maintain temperature, | ||
|
| not increase temperature. |
| |
|
|
| ||
| Hose temperature setpoint too low. | Check. Increase if necessary to | ||
|
| maintain heat. |
| |
|
|
| ||
| Flow too high. | Use smaller mix chamber. Decrease | ||
|
| pressure. |
|
|
|
|
| ||
| Low current; FTS not installed. | Install FTS, see operation manual. | ||
|
|
| ||
| Hose heat zone not turned on long | Allow hose to heat up, or preheat | ||
| enough. | fluid. |
|
|
|
|
| ||
| Loose hose electrical connections. | Check connections. Repair as neces- | ||
|
| sary. |
|
|
|
|
|
|
|