Graco 309909H Pump Air Control Meter Air Control, No. Part No. Description Qty

Page 53

287230 Pump Air Control

287231 Meter Air Control

Ref.

 

No. Part No. Description

Qty.

Parts

Ref.

 

No. Part No. Description

Qty.

201

15D814

MANIFOLD, air; 287230 only

2

 

15D814

MANIFOLD, air; 287231 only

1

202

206197

REGULATOR, air; 1/2 npt(f) inlet

1

 

 

and outlet; 287230 only;

 

 

 

see manual 308168

1

203

119240

CAP, pipe, 1/2 in. (13 mm)

204

101689

GAUGE, air pressure; 287230

2

 

 

only

1

 

101689

GAUGE, air pressure; 287231

 

 

only

3

205

112678

PLUG; 1/4 npt; 287230 only

206

118762

VALVE, ball, bleed-type;

1

 

 

1/2 npt(fbe)

 

*These parts are included in 287230 Air Control only.

*204

207113498 VALVE, safety relief;

110 psi (0.8 MPa, 8 bar)

208119246 STANDOFF

209100081 BUSHING, pipe; 1/2 npt(m) x 3/8 npt(f)

210C19024 ELBOW, swivel; 1/2 npt(m) x 1/2 npsm(f)

203

205*

201*

202*

205*

1

4

1

1

208

*205

207

204

208

206

201

209

210

TI4601a

309909H

53

Image 53
Contents Important Safety Instructions Repair PartsManual Conventions ContentsSeries Description Psi MPa, bar Approvals ProMix Easy ModelsComponent Manuals in English Description Related ManualsFire and Explosion Hazard Equipment Misuse Hazard Fluid Manifold to Gun Pressure Relief ProcedurePump to Fluid Manifold Problem Solution MaintenanceProblem Cause Solution TroubleshootingCircuit. See Electrical Schematic, Relieve pressure. Install larger tip. Follow Code Startup ErrorsOperating Errors Testing Error Code Alarm Active Problem CauseReplacing Air Filter Element RepairRemoval Software UpgradesReplacing Main Circuit Board Replacing Display Circuit Board Alternator Repair Pneumatic ControlReplacing Alternator Regulator Replacing AlarmReplacing Solenoids Follow Pressure Relief Procedure, Dispense Valve/Mix Manifold AssemblySchematic Pump Solenoid Expansion Board Schematic Main Control Board SchematicMain Control Board LEDs PinPart No Series A, Pump-based, Cart-mounted Air Spray Unit Parts78 Ref Cable ConnectionsNo. Part No. Description Pump and Meter-based, Wall-mounted Air Spray Units Pump Solenoid Cable Connections Description Qty See page 27 for model numbers and descriptionsPump-based, Wall-mounted Air Spray Units 494025 24 Ref See page 30 for model numbers and descriptions Meter-based, Wall-mounted High Pressure Units 65 Ref 4025 24 Ref See page 33 for model numbers and descriptions Pump-based, Wall-mounted High Pressure Units Muffler See page 36 for model numbers and descriptions Ft 5.2 ft Pump and Meter-based, Wall-mounted High Pressure Units TI4908a Muffler See page 40 for model numbers and descriptionsCheck Valve Side Tube Connections, Low Pressure PumpsP2P1 Tube Connections, High Pressure PumpsC1G1 P2 M1 Tube Connections, MetersPneumatic Schematic Part No. Description Qty Intrinsically Safe Pneumatic ControlSolenoid Module 306 Detail Alternator Module 304 DetailNon-intrinsically Safe Pneumatic Control 307 Display User InterfaceNo. Part No. Description Qty Pump Air Control Meter Air ControlTechnical Data Technical Data Graco Information Graco Standard Warranty