Alarms
Code | Alarm | Active | Problem | Cause | |
|
|
|
|
| |
|
|
|
|
| |
| Operating Errors |
|
|
| |
| (continued) |
|
|
| |
22 | High Ratio (units with | Spray | Mix ratio higher than | Flow rate too high | |
| meter[s] only) |
| Target + Tolerance | Slow actuation of dispense valve A or B | |
|
|
|
| ||
23 | Low Ratio (units with | Spray | Mix ratio lower than | ||
Clogged flow meter | |||||
| meter[s] only) |
| Target - Tolerance | ||
|
|
|
|
| |
24 | Dose Timeout A (units | Spray | Air flow switch indicates | Air flow switch stuck open. | |
| with meter[s] only) |
| more than 40 sec of air | Atomizing air leak downstream of air flow switch. | |
|
|
| flow without dose com- | ||
25 | Dose Timeout B (units |
| |||
| pleting |
| |||
| with meter[s] only) |
| Clogged flow meter. | ||
|
|
| |||
|
|
|
| ||
|
|
|
| Gun triggered without fluid (dusting parts) | |
|
|
|
|
| |
26 | Park Timeout | Park | Pumps not at bottom of | Sampling valves closed, or gun not triggered. | |
|
| stroke |
| ||
|
|
|
|
| |
| Testing Error |
|
|
| |
15 | Piston packing/ball A* | Test | Pump does not com- | Piston packing or ball check failure | |
|
|
| pletely stall in up stroke |
| |
16 | Piston packing/ball B* |
|
| ||
|
|
| |||
|
|
|
|
| |
17 | Inlet Ball A* | Test | Pump does not com- | Intake valve ball check failure | |
|
|
| pletely stall in downstroke |
| |
18 | Inlet Ball B* |
|
| ||
|
|
| |||
|
|
|
|
| |
19 | Dispense Valve A* | Test | Pump does not com- | Throat packing or dispense valve failure | |
|
|
| pletely stall in both up |
| |
20 | Dispense Valve B* |
|
| ||
| and down strokes |
| |||
|
|
|
| ||
|
|
|
|
| |
27 | Pump Calibration | Run A | Pump doesn’t run | Sampling valves closed. | |
| Timeout A |
| through calibration. |
| |
|
|
|
|
| |
28 | Pump Calibration | Run B |
|
| |
| Timeout B |
|
|
| |
|
|
|
|
|
14 | 309909H |