Shure FP410 Operating Voltage, Temperature Range, Overall Dimensions, Net Weight, Certifications

Page 7

Operating Voltage

AC Operation: 100 to 120 Vac rated nominal, 80 to 132 Vac fully operational (FP410); 230 Vac rated nominal, 160 to 264 Vac fully operational (FP410E), 50/60 Hz, 8 W

DC Operation: 18 Vdc nominal at 25 mA typical no--signal, 33 mA typical at 0 VU (+4 dBm) output with 600τ load; 6 Vdc minimum; battery life approximately 12 hours with alkaline batteries at +4 dBm output in continuous use at room tem- perature; two 9--volt batteries (type NEDA 1604A)

Temperature Range

Operating . . . . . . . . . . . . . --18to 57C (0to 135F ) Storage . . . . . . . . . . . . . . . --29to 71C (--20to 160F)

Questions & Answers

Overall Dimensions

44.5mm H x 368 mm W x 210 mm D (13/4 x 141/2 x 81/4 in- ches)(not including feet)

Net Weight

2.27 kg (5 lb)

Certifications

FP410: Listed by Underwriters Laboratories, Inc., listed as Certified by Canadian Standards Association.

FP410E: Conforms to European Union directives, eligible to bear CE marking;VDE GS-certified to EN 60 065; meets Eu- ropean Union EMC Immunity Requirements (EN 50 082-1, 1992).

Questions about your FP410 installation? This section lists the most common questions asked about Shure’s automatic microphone systems. Maybe your question is among the fol- lowing. If not, contact Shure’s Customer Service Department.

Q. Why don’t I get any sound output from my FP410?

A. Assuming that your power amp, tape deck, speakers, etc. are good, possibly it’s because:

The Channel or Master Gain controls are turned down,

A microphone is not connected,

A rear--panel Mic/Line input or output switch or the Phan- tom On--Off switch is improperly set,

The FP410 isn’t plugged in or doesn’t have batteries in- stalled, or

The Power switch isn’t on.

Check these items and make the required correction. Q. Still doesn’t work. Why?

A. Maybe you have a defective microphone or cable. While lis- tening to headphones plugged into one of the front--panel Phone jacks, try replacing the suspect microphone or cable with one known to be good.

Q. Why does a microphone turn on or off erratically, causing speech dropouts?

A.Excessive room noise (such as from air--handling or audio-- visual equipment) can be a cause. Reduce the room noise, the proximity of the noise to any mic, and/or the talker--to--mic dis- tance. A loud talker close to their microphone or with their Channel Gain control set too high can sometimes inhibit prop- er microphone activation by a “weaker” talker who is too far from their microphone or has their Channel Gain control set too low. Balance the microphones by repositioning and/or re- setting the Channel Gain controls in accordance with the Op- eration section.

IMPORTANT: Best results are generally obtained when the Last Mic Lock--On is not defeated and the Off--Attenuation is

13 dB (modifiable function switches up). Difficult situations may be aided by changing the Hold Time from 0.4 to 1.0 sec- ond (modifiable function switch down).

Q. Why am I getting howling through my loudspeakers?

A. For the same reason that howling is present in any PA sys- tem: your mics are picking up the speaker sound and reampli- fying it. Move the speakers or mics, or turn down the gain con- trols, to avoid the howling. Automatic operation does provide more output level before howling than manual operation, but the system still can howl.

Q. Why does the FP410 output sound distorted?

A. The Channel, Master or Phones Gain control may be set too high. Set the Channel Gain according to the Operation section. Set the Master Gain to avoid excessive red LED indications on the Output Level meter, or switch the Limiter in. Turn down the Phones control. Check the following equipment levels.

Q. Why does the speech level go up when I switch from Manu- al to Automatic operation?

A. This is normal and proper operation for any automatic mix- er.When switched to Automatic, the FP410 attenuates any in- put channel not being used. Internally, this removes the inac- tive channels from the FP410 mix bus. This action increases the perceived level of any active input channel. For example, the audio gain increase will be 6 dB when going from four to only one activated microphone channel.

Q. Why is one of my four mics very noisy?

A. Assuming the mic is operating properly (you can check this by substituting with another mic), you probably have a con- stant noise source such as air--moving equipment or a defec- tive fluorescent light ballast in the trouble area. This ambient noise source can be unnoticed until it’s picked up by a mic: then it’s extremely annoying. If you can’t repair, turn off or lower the noise source, try relocating the mic to eliminate or at least lower the noise. If this is not possible, use the FP410 in the Manual mode to avoid microphone activation problems and accept the noisy output.

7

Image 7
Contents FP410 Portable Automatic Mixer CONTROLS, CONNECTORS, Indicators Installation and Operation Modifiable Functions Additional Information Voltage Gain Output Input Line Mic Head Common Mode RejectionPhantom Power Frequency Response controls centeredOperating Voltage Temperature RangeOverall Dimensions Net WeightFP410 Block Diagram Caractéristiques FrançaisVeuillez Prendre Note COMMANDES, CONNECTEURS, Indicateurs Voir FigureFonctions Modifiables Installation ET FonctionnementInstallation du mélangeur FonctionnementInformations Supplementaires Fonctions Internes Modifiables AvertissementSpecifications Accessoires ET Pieces DE RechangePoids net Dimensions hors toutTension de régime Domaine de températuresEINSTELLER, Anschlüsse UND Anzeigen siehe Abbil- dung Technische BesonderheitenBedienung Installation des MischersBitte Beachten Aufbau UND BedienungZusätzliche Informationen Intern Modifizierbare Funktionen WarnungMitgeliefertes Zubehör UND Ersatzteile Technische Daten Características EspañolInstalación del mezclador CONTROLES, CONECTADORES, Indicadores Vea la FiguraAdvertencia Instalación Y OperaciónFunciones Modificables OperaciónFunciones Internas Modificables Advertencia Especificaciones Información AdicionalPolaridad Dimensiones globalesZumbido y ruido Rechazo en modo comúnCaratteristiche CONTROLLI, CONNETTORI, Indicatori Vedere figuraMessa in Opera E Funzionamento AvvertenzaMessa in opera del miscelatore Informazioni Addizionali FunzionamentoFunzioni Modificabili Funzioni Modificabili Interne AttenzioneSpecificazioni Miscelatori collegatiCavi di collegamento FP410E Ed I Quadri di Comando di MissaggioPolarità Dimensioni generaliRonzio e rumore Scarto del modo comuneMeter Limiter OFF Hold Last MIC Phantom Threshold FP410 Block Diagram
Related manuals
Manual 9 pages 52.37 Kb

FP410 specifications

The Shure FP410 is a compact, portable dual-channel wireless receiver designed for professional audio applications, particularly in the fields of video production, broadcasting, and live events. It embodies Shure’s commitment to high-quality audio transmission, reliability, and ease of use, making it an ideal choice for audio professionals who demand superior performance in their equipment.

One of the standout features of the FP410 is its dual-channel capability, allowing users to receive audio signals from two separate transmitters simultaneously. This is particularly beneficial in situations where multiple audio sources need to be captured independently, such as interviews or multi-person presentations. The unit operates in the 500 to 600 MHz frequency range, providing a wide selection of channels and minimizing the risk of interference from other wireless devices.

The FP410 is equipped with Shure's advanced digital signal processing technology, enabling it to deliver clear, high-fidelity audio with minimal latency. The unit utilizes a proprietary Automatic Frequency Selection feature, which scans the environment and selects the best available frequency, ensuring a stable and reliable connection. Additionally, it features a frequency diversity mode that provides even further protection against dropouts and interference by simultaneously receiving signals on two separate frequencies.

The design of the FP410 is rugged yet lightweight, making it suitable for both stationary setups and mobile use. It features a large, easy-to-read LCD screen that displays essential information, including battery life, signal strength, and channel selection, allowing users to monitor their setup at a glance. The receiver can be powered via AA batteries or an external power supply, adding flexibility for various field conditions.

Another notable characteristic of the FP410 is its versatility in connectivity options. It includes balanced XLR and unbalanced 1/4-inch output connections, providing compatibility with a range of audio devices, from cameras to mixers. This adaptability makes it a valuable tool for videographers, musicians, and sound engineers alike.

In summary, the Shure FP410 represents an advanced solution for wireless audio transmission. With its dual-channel operation, intelligent frequency selection, robust design, and versatile connectivity, it meets the demands of professional audio applications while ensuring exceptional sound quality and reliability. Whether for location shoots, live broadcasts, or stage performances, the FP410 is engineered to excel in any environment, solidifying Shure’s reputation as a leader in audio technology.