Fostex LM16 manual R peak indicators, R meters between 7

Page 37

Model LM16 [Upgrading the software]

• L and R peak indicators

Depending on the major version number, each of the L and R peak indicators is lit or unlit as shown in the table below.

PEAK indicator

Value L

R

 

1

 

 

 

2

 

 

 

3

 

 

 

4

 

 

: lit

• L and R meters (between 7 and -30)

The L meter shows the minor version number (the second digit), while the R meter shows the sub minor version (the third digit). See the table below for the relation between the number and the lighting condition.

L meter

 

 

 

 

 

 

 

 

R meter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

 

 

 

 

 

 

 

 

 

 

0

1

2

3

4

5

6

7

8

9

LED

 

 

 

 

HEX

 

 

 

7

4

2

0

- 2

- 4

- 7

- 10

- 20

-30

: lit

<Example>: The following shows the meter con- dition when the current version is "Version

1.23".Unlit

How to upgrade the version

The following explains how to upgrade the software version.

You can download the upgraded software (lat- est version) from the FOSTEX website (http:/ /www.fostex.com/). After downloading the file, copy it to a USB memory stick. (The down- loaded file has the file extension ".mot". See the FOSTEX website for details about down- loading.)

<Note>: If you cannot download the soft- ware file from the FOSTEX website, ask your local FOSTEX dealer or service station.

(1)Turn on the power of the unit.

(2)Connect the USB memory stick to which you copied the downloaded file to the [USB (HOST)] port.

 

 

 

 

 

 

INPUT

 

 

 

 

 

GROUP (+4dBu)

EFF SEND (-2dBu)

AUX SEND (-2dBu)

INSERT

INSERT

INSERT

INSERT

R

STEREO OUT (+4dBu)

L

ST MIX OUT (-10dBV)

USB

MIDI OUT

 

CONTROLLER

 

 

 

 

 

 

 

 

 

 

 

PHAN

USB memory stick

After reading the file information, the unit enter the version upgrade mode and shows the version information (version number and date) of the file using the [PEAK] indicators on input channels as well as the L and R meters and peak indi- cators, while the [STOP] and [REC] indi- cators start flashing.

(See the previous section for details about how the information is shown.)

<Note>: To cancel performing upgrade, press the [STOP] key while the [STOP] and [REC] indicators are flashing.

The unit exits the upgrade mode.

(3)Press the [REC] key.

The unit performs upgrade.

When upgrade is completed, the system automatically restarts the unit.

Lit

Lit

<Memo>: While performing upgrade, the [PEAK] indicators of all channels are lit. While performing upgrade of the main unit, the [PHANTOM 1-8] indicator slowly flashes. While performing up- grade of the control unit, the [PHAN- TOM 9-16] indicator slowly flashes.

37

Image 37
Contents Model LM16 Safety Instructions Important Safety Instructions Table of contents Adjusting the input level Low-cut filter Limiter Equalizer Signal flow of the mixer Connecting sourcesUpgrading the software Precautions on installation About power supplyAbout version upgrade IntroductionCondensation Cleaning the exteriorAbout damage About CAT-5 cableOverview Main features Unpacking the carton Before using the unitUsage examples of LM16 Setting the main unit and control unit separatelyIntegrating the main unit and control unit Mounting the main unit and control unit on the rackNecessary items Integrating the control unit and main unitRack mount adaptor After attaching the adaptor Preparation of power supply Connecting the power cordConnection example live stage Connection to external devicesMTR Connection example home recordingBalanced Balanced and unbalanced inputs/outputsNames and functions Control unit input channel 1 through Mute switch POST/PRE switch14 ST/1-2/3-4 assign switches Solo switchSUB in jacks / SUB in control Control unit Master channelMonitor section Internal effects section Phantom 1-8, 9-16 indicatorsControl section 24 27 EFF Send control / Solo switch AUX Send controls / Solo switchesAssign to Stereo OUT switches Output Limiter switchMain unit rear panel Control unit rear panelController connector Phantom 1-8, 9-16 switchesGroup OUT 1, 2, 3, 4 connectors Stereo OUT L, R connectorsMixer basics Signal flow of the mixerAdjusting the input level Connecting sourcesConnecting sources to the input connectors Phantom power supply settingEqualizer Gain adjustment while monitoringLow-cut filter LimiterUsing AUX 1, 2 Using an external effect processorPre-fader Post-faderUsing Insert Using the internal effects processorApplying the internal effects About the effect types MonitoringSolo monitor Channel groupingSet the Source switches on channels 15 and 16 to TRK Using SUBSet the ST assign switches on channels 15 and 16 to on Block diagram Showing version information Showing date informationR meters between 7 R peak indicatorsInputs/Outputs SpecificationsPower Consumption approx W Physical dimensionsGeneral Main unitMMC Command List Model LM16 Midi Implementation ChartDeclaration of EC Directive Forthe US Customers only Fostex America Limited Warranty Shipping Effect processor IndexMemo Page Fostex CO