Dynacord DRM 4000 owner manual Basic Configuration

Page 25

C O N FIGURING THE DRM 4000

Legend to the table on the DRM 4000 FACTORY CONFIGURATION leaflet:

BASIC CONFIGURATION:

The BASIC CONFIGURATION is active when no CONTROL

 

 

INPUT is connected to ground. The BASIC CONFIGURATION

 

 

always has the lowest priority.

CONTACT 1-8:

 

The DRM 4000’s active configuration accords to the CONTROL

 

 

INPUT, which is connected to ground, as long as no other

 

 

CONTROL INPUT with a higher priority setting is connected

 

 

to ground.

PRIORITY:

 

Each CONTROL INPUT has an assigned PRIORITY between

 

 

1 and 8. PRIORITY 0 - the lowest priority level - relates to the

 

 

BASIC CONFIGURATION. The CONTROL INPUT with the

 

 

highest priority setting is the active one (PRIORITY 8 represents

 

 

the highest priority level) when several CONTROL INPUTS

 

 

are connected to ground.

Routing:

Off

The input signal is not assigned to any output.

 

Mono A

The input signal is only assigned to output A. AUX-inputs are

 

 

summed for monaural output.

 

Mono B

The input signal is only assigned to output B. AUX-inputs are

 

 

summed for monaural output.

 

Dual

The input signal is assigned to the outputs A and B.

 

 

AUX-inputs are summed for monaural output via the outputs

 

 

A and B.

 

Stereo

AUX-input L is assigned to output A while AUX-input R is

 

 

assigned to output B. (this option is only available for AUX-inputs)

 

No Change

The control input parameters are not changed from the BASIC

 

 

CONFIGURATION.

Mute:

No Mute

The output signal is connected through to the masters A resp. B.

 

Mute On

Output relays switch the output signal off of masters A resp. B.

 

No Change

The control input parameters are not changed from the

 

 

BASIC CONFIGURATION.

VCA:

 

The MASTER outputs A resp. B are attenuated by the according

 

 

value in dB.

Priority Override:

Enable

MIC/LINE-input activates ducking control.

 

Disable

MIC/LINE-input does not activate ducking control.

Ducking:

Ducking Active

Ducking control is activated by the contact.

 

Auto Ducking

Ducking control is automatically activated, when the level in

 

 

MIC/LINE 1 or 2 is exceeding the Ducking Threshold (automatic

 

 

level detection function). Please note, that is a precondition

 

 

routing MIC/LINE 1 or 2 to the corresponding Master output and

 

 

setting the parameter Priority Override to Enable.

 

No Change

The control input’s parameters are not changed from the

 

 

BASIC CONFIGURATION.

8-2

Image 25
Contents DRM For US, Canada and Japan only Safety Component has to be Replaced with Original Part onlyContents Characteristics Introduction DRM 4000 CharacteristicsIntroduction Field of ApplicationUnpacking and Warranty Controls and Connections Controls and Connections12, POWER-switch Ducking indicators a / BTone Control LO / HI Control AUX18, Direct OUT 16, Control27, +24V-switch 26, PAD-switch20, Send output 21, MIX in inputQuick Start Uick StartInstallation and Connections Installation and ConnectionsGeneral Notes Input Assignment 1 MIC/LINE inputsOutput Assignment 4.3.1 Master outputs AUX and MIX in inputsSend outputs Direct OutputsControl Inputs Control InputsExternal VCA-Control Level Settings Power-On OperationLevel Adjustment for MIC/LINE-inputs Initial OperationLevel Adjustment for AUX-inputs Special Features of the DRM Special Features of the DRMUsing Ducking Control Limiter OperationUsing The Unit Together With The DPM Software Editor DRM Installation NotesSoftware Editor DRM System RequirementsMenus And The Toolbar File Menu Software Description 7.4.1 GeneralView Menu Basic ConfigurationCommunication Menu About MenuMIC/LINE-inputs Name and CommentAux-inputs OutputsPriority Control Inputs View Status Online Control / StatusTest N Figuring the DRM Configuring the DRMBasic Configuration Internal Settings / Extensions Internal SettingsInternal Configuration Possibilities Low Cut Filter AUX Sensitivity Selection Limiter SettingsHow to install the Input Transformer NRS 90233, EDP-No HOW to Install ExtensionsHow to install the Output Transformer NRS 90227, EDP-No How to install Interface-Boards Specifications SpecificationsPeci F I C a T IO N S Specific a Tions User ConfigurationSpecifica Tions Block diagram 10.4 RS-232 Interface Programmer’s Instructions Switching Contacts Via SoftwareREMOTE/PRIO value Online-Access to all ParametersDimensions Garantie Warranty